Operation; Water Connection; Power Connection - Kärcher HDS 5/11 U/UX Instructions Manual

Hide thumbs Also See for HDS 5/11 U/UX:
Table of Contents

Advertisement

Water connection

Warning
Observe regulations of water supplier.
According to the applicable regula-
tions, the appliance must never be
used on the drinking water supply
without a system separator. Use a
suitable system separator manufactured by
KÄRCHER; or, as an alternative, a system
separator as per EN 12729 Type BA. Water
flowing through a system separator is con-
sidered non-drinkable.
Caution
Always connect the system separator to
the water supply, never directly to the appli-
ance!
For connection values refer to technical
specifications
 Attach supply hose (minimum length
7.5 m, minimum diameter 1/2") to the
water supply set by means of a hose
clamp.
 Connect the supply hose to the water
connection point of the machine and at
the water supply point (for e.g. a tap).
Note: The supply hose and the hose clamp
are not included in the scope of delivery.
Suck in water from vessel
 Connect suction hose (minimum diame-
ter 1/2") with filter (accessory) to the
water connection point.
Max. suck height: 0.5 m
Danger
Never suck in water from a drinking water
container. Never suck in liquids which con-
tain solvents like lacquer thinner, petrol, oil
or unfiltered water. The sealings within the
device are not solvent resistant. The spray
mist of solvents is highly inflammable, ex-
plosive and poisonous.
20

Power connection

For connection values, see technical
data and type plate.
The electrical connections must be
done by an electrician according to IEC
60364-1.
 Set the appliance switch to "0/OFF".
 Plug in the main plug.
Danger
Danger of injury by electric shock.
Unsuitable extension cables can be
hazardous. Only use extension cables
outdoors which have been approved for
this purpose and labelled with a suffi-
cient cable cross section:
Always unwind extension lines com-
pletely.
The plug and coupling of the extension
cable used must be watertight.
Caution
The highest allowed net impedance at the
electrical connection point (refer to techni-
cal data) is not to be exceeded. In case of
confusion regarding the power impedance
present on your connection, please contact
your utilities provider.
Danger
Risk of explosion!
Do not spray flammable liquids.
Caution
Never operate device with empty fuel
tank The fuel pump will otherwise be
destroyed. This also applies to cold wa-
ter operation.
Risk of damage! Never operate the ap-
pliance without a filter in the water con-
nection.
Risk of damage! Do not place any ob-
jects (hose,etc.) on or over the chim-
ney.
Device with hose drum:
Always unwind high pressure hose
completely
– 4
EN

Operation

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents