Headlights

Use Button 2 to turn on/off the headlights. When the
engine is in start mode, press the button to turn the
headlights on. A blinking Button 2 light signals that
one or both headlights are not working.
The headlights can also be used when the ignition
switch is not activated or the unit is not running. Press
Button 2 and the headlights will stay lit for one minute.
For a longer headlight mode, press and hold the
button for five seconds. The headlights will flash twice
to acknowledge and will stay on for five minutes.

Weak Battery

WARNING!
Lead-acid batteries generate
explosive gases. Keep sparks, flame
and smoking materials away from
batteries. Always wear eye protection
when around batteries.
If the battery is too weak to start the engine, it should
be recharged. (See Battery in the Maintenance
section.)

Jumper Cables Use

1. Connect each end of the RED cable to the
POSITIVE (+) terminal on each battery, taking
care not to short against chassis.
2. Connect one end of the BLACK cable to the
NEGATIVE (-) terminal of the fully charged battery.
3. Connect the other end of the BLACK cable to a
good CHASSIS GROUND on the mower with the
discharged battery away from the fuel tank and
battery.
To remove cables, reverse order
4. Remove BLACK cable first from chassis and then
from the fully charged battery.
5. Remove RED cable last from both batteries.
36
OPERATION
Headlight button
Jumper cable connection
IMPORTANT INFORMATION
Your mower is equipped with a 12-volt negative
grounded system. The other vehicle must also
be a 12-volt negative grounded system. Do not
use your mower to start other vehicles.