When mountain climbing, you can specify a reference altitude value in accordance
with a marker along the way or altitude information from a map. After that, the
altitude readings produced by the watch will be more accurate than they would
without a reference altitude value.
To take an altimeter reading
1. Make sure the watch is in the Timekeeping Mode.
Current time
Current time
2. Press
to start Altimeter measurement.
ALTI will appear on the display, indicating that
Altimeter measurement is in progress. The first
reading will appear on the display after about four
or five seconds.
The current altitude value is displayed in units of 5
meters (20 feet).
After the first reading is obtained, the watch
continues to take altimeter readings automatically
Current
Current
Temperature
Temperature
every five seconds for the first three minutes, and
altitude
altitude
then every two minutes after that.
If you leave the watch in the Altimeter Mode, it will update the displayed altitude
value regularly.
Temperature is measured in the Barometer/Thermometer Mode and in the
Altimeter Mode. For details about temperature readings, see "Temperature".
3. After you are finished using the Altimeter, press
Mode and stop auto measurement.
The watch will return to the Timekeeping Mode automatically if you do not
perform any operation for about 10 hours after entering the Altimeter Mode.
Note
The measurement range for altitude is –700 to 10,000 meters (–2,300 to 32,800
feet).
The displayed altitude value changes to - - - - if an altitude reading falls outside the
measurement range. An altitude value will reappear as soon as the altitude reading
is within the allowable range.
Normally, displayed altitude values are based on the watch's preset conversion
values. You also can specify a reference altitude value, if you want. See "Specifying
a Reference Altitude Value" below.
You can change the unit for displayed altitude values to either meters (m) or feet (ft).
See "To specify temperature, barometric pressure, and altitude units".
Specifying a Reference Altitude Value
The altitude readings produced by this watch are subject to error caused by changes
in air pressure. Because of this, we recommend that you update the reference altitude
value whenever accurate altitude information is available during your climb. After you
specify a reference altitude value, the watch adjusts its air-pressure-to-altitude
conversion calculation accordingly.
To specify a reference altitude value
1. In the Altimeter Mode, hold down
reference altitude value starts to flash. This is the
setting screen.
Before the reference altitude value starts to flash,
the message SET Hold will appear on the display.
Keep
depressed until SET Hold disappears.
2. Press
(+) or
altitude value by 5 meters (or 20 feet).
Specify a reference altitude value based on
accurate altitude information about your current
location from a map, etc.
You can set the reference altitude value within the range of –10,000 to 10,000
meters (–32,800 to 32,800 feet).
Pressing
and
at the same time returns to OFF (no reference altitude value),
so the watch performs air pressure to altitude conversions based on preset data
only.
3. Press
to exit the setting screen.
How does the altimeter work?
Generally, air pressure and temperature decrease as altitude increases. This watch
bases its altitude measurements on International Standard Atmosphere (ISA) values
stipulated by the International Civil Aviation Organization (ICAO). These values define
relationships between altitude, air pressure, and temperature.
Altitude
Air Pressure
616 hPa
4000 m
About 8 hPa per 100 m
3500 m
701 hPa
3000 m
About 9 hPa per 100 m
2500 m
795 hPa
2000 m
About 10 hPa per 100 m
1500 m
About 11 hPa per 100 m
899 hPa
1000 m
500 m
About 12 hPa per 100 m
1013 hPa
0 m
14000 ft.
19.03 inHg
12000 ft.
About 0.15 inHg per 200 ft.
10000 ft.
22.23 inHg
8000 ft.
About 0.17 inHg per 200 ft.
6000 ft.
About 0.192 inHg per 200 ft.
25.84 inHg
4000 ft.
2000 ft.
About 0.21 inHg per 200 ft.
0 ft.
29.92 inHg
Source: International Civil Aviation Organization
Note that the following conditions will prevent you from obtaining accurate readings:
When air pressure changes because of changes in the weather
Extreme temperature changes
When the watch itself is subjected to strong impact
There are two standard methods of expressing altitude: Absolute altitude and relative
altitude. Absolute altitude expresses an absolute height above sea level. Relative
altitude expresses the difference between the height of two different places.
Height of building 130 m
(relative altitude)
to return to the Timekeeping
until the current
(–) to change the current reference
Temperature
–11°C
–4.5°C
About 6.5°C
per 1000 m
2°C
8.5°C
15°C
16.2°F
30.5°F
About 3.6°F
per 1000 ft.
44.7°F
59.0°F
Rooftop at an altitude of
230 m above sea level
(absolute altitude)
Sea Level
Altimeter Precautions
This watch estimates altitude based on air pressure. This means that altitude
readings for the same location may vary if air pressure changes.
The semiconductor pressure sensor used by the watch for altitude measurements
is also affected by temperature. When taking altitude measurements, do not subject
the watch to temperature changes.
Do not rely upon this watch for altitude measurements or perform button operations
while sky diving, hang gliding, or paragliding, while riding a gyrocopter, glider, or
any other aircraft, or while engaging in any other activity where there is the chance
of sudden altitude changes.
Do not use this watch for measuring altitude in applications that demand
professional or industrial level precision.
Remember that the air inside of a commercial aircraft is pressurized. Because of
this, the readings produced by this watch will not match the altitude readings
announced or indicated the flight crew.
Specifying Temperature, Barometric Pressure, and Altitude Units
Use the procedure below to specify the temperature, barometric pressure, and altitude
units to be used in the Barometer/Thermometer Mode and the Altimeter Mode.
Important!
When TYO (Tokyo) is selected as the Home City, the
altitude unit is set automatically to meters (m), the
barometric pressure unit to hectopascals (hPa), and the
temperature unit to Celsius (°C). These settings cannot
be changed.
To specify temperature, barometric pressure, and altitude units
1. In the Timekeeping Mode, hold down
to flash. This is the city code setting screen.
Before the city code starts to flash, the message SET Hold will appear on
the display. Keep
depressed until SET Hold disappears and the city code
starts to flash.
2. Keep pressing
until TEMP (temperature), ALTI (altitude), or BARO (barometric
pressure) appears in the upper left corner of the screen.
See step 3 under "To change the current time and date settings" for information
about how to scroll through setting screens.
3. Perform the operations below to specify the units you want.
To specify this unit: Press this key: To toggle between these settings:
Temperature
°C (Celsius) and °F (Fahrenheit)
Altitude
m (meters) and ft (feet)
Barometric Pressure
hPa (hectopascals) and inHg (inches of mercury)
4. After the settings are the way you want, press
Precautions Concerning Simultaneous Measurement of Altitude and Temperature
Though you can perform altitude and temperature measurements at the same time,
you should remember that each of these measurements requires different conditions
for best results. With temperature measurement, it is best to remove the watch from
your wrist in order to eliminate the effects of body heat. In the case of altitude
measurement, on the other hand, it is better to leave the watch on your wrist, because
doing so keeps the watch at a constant temperature, which contributes to more
accurate altitude measurements.
To give altitude measurement priority, leave the watch on your wrist or in any other
location where the temperature of the watch is kept constant.
To give temperature measurement priority, remove the watch from your wrist and
allow it to hang freely from your bag or in another location where it is not exposed
to direct sunlight. Note that removing the watch from your wrist can affect pressure
sensor readings momentarily.

Checking the Current Time in a Different Time Zone

You can use the World Time Mode to view the current
Currently selected
Currently selected
time in one of 31 time zones (48 cities) around the globe.
World Time City
World Time City
The city that is currently selected in the World Time Mode
is called the "World Time City".
To enter the World Time Mode
Use
to select the World Time Mode (WT) as shown in
"Selecting a Mode".
WT will appear on the display for about one second.
Next, the display will change to show the city code of
Current Timekeeping
Current Timekeeping
the currently selected World Time City.
Mode time
Mode time
To view the time in another time zone
Current time in the currently
Current time in the currently
In the World Time Mode, use
selected World Time City
selected World Time City
city codes.
To specify standard time or daylight saving time (DST) for a city
1. In the World Time Mode, use
city code (time zone) whose Standard Time/Daylight
Saving Time setting you want to change.
2. Hold down
and then disappears. Release
disappears.
This toggles the city code you selected in step
1 between Daylight Saving Time (DST indicator
DST indicator
DST indicator
displayed) and standard time (DST indicator not
displayed).
You cannot use the World Time Mode to change the current standard time/
daylight saving time (DST) setting of the Home City.
Note that you cannot switch between standard time/daylight saving time
(DST) while UTC is selected as the World Time City.
Note that the standard time/daylight saving time (DST) setting affects only the
currently selected time zone. Other time zones are not affected.
until the currently selected city code starts
to exit the setting screen.
(East) to scroll through
(East) to display the
until DST Hold appears on the display
after DST Hold

Hide quick links: