6. REMOTE SWITCHING

Various switching configurations can be made using an interface cable.
Commonly used switching configurations are explained below.
Camera (or other switching device) leading
The illuminator may be activated remotely by a volt-free contact latched
across the TELEMETRY input. Use interface cable (UFLED-CI-5M).
Looping multiple illuminators
Multiple illuminators can be linked for synchronous illuminator switching.
Use link cable (UFLED-CL-1M) between the DAY/NIGHT CAMERA output
and the TELEMETRY input as shown in the diagram below.
Illuminator 3
UFLED-CL-1M
Illuminator leading
The DAY/NIGHT CAMERA output may be used to switch the camera
between the Day and Night mode. Use interface cable (UFLED-CI-5M).
Illuminator
UFLED-CI-5M
Illuminator 2
Illuminator 1
UFLED-CL-1M
UFLED-CI-5M
Illuminator
UFLED-CI-5M