Determining Delay Switch Positions By Using A Delay Measuring Tool - Bosch INTEGRUS Installation And Operating Manual

Digital infra-red language distribution system
Hide thumbs Also See for INTEGRUS:
Table of Contents

Advertisement

INTEGRUS | Digital Infra-red Language Distribution System
0m
R
R3
R5
0m
Figure 1.26 System with five radiators and measured cable lengths
Table 1.1 Calculation of the cable signal delays
Radiator
Total cable
number
length [m]
1
30
2
30+20 = 50
3
20
4
30
5
30+20 = 50
The used cable signal delay per meter is an example. Use the actual signal delay per meter in this calculation as specified by the
manufacturer.
1.5.1.2

Determining delay switch positions by using a delay measuring tool

The most accurate way to determine the cable signal delays is to measure the actual signal delay for each radiator as described in
the following procedure:
1.
Disconnect the cable from a radiator output of the transmitter and connect this to a delay measurement tool.
2.
Disconnect a radiator from this cable.
3.
Measure the impulse response time (in ns) of the cable(s) between the transmitter and the radiator.
4.
Reconnect the cable to the radiator and repeat steps 2 to 4 for the other radiators that are connected to the same
transmitter output.
5.
Reconnect the cable to the transmitter and repeat step 1 to 5 for the other radiator outputs of the transmitter.
6.
Divide the impulse response times for each radiator by two. These are the cable signal delays for each radiator.
7.
Determine the maximum signal delay.
8.
Calculate for each radiator the signal delay difference with the maximum signal delay.
9.
Divide the signal delay difference by 33. The rounded off figure is the delay switch position for that radiator.
10. Add delay switch positions to radiators under a balcony, if applicable (see section 1.5.3)
11. Set the delay switches to the calculated delay switch positions.
: Turn the delay switches carefully to a new position until you feel that it clicks into position, to prevent that a switch is positioned
between two numbers, which would result in a wrong delay setting.
30m
R1
0m
30m
R4
Cable signal delay
Cable sgnal
per meter [ns/m]
delay [ns]
5.6
30*5.6 = 168
5.6
50*5.6 = 280
5.6
20*5.6 = 112
5.6
30*5.6 = 168
5.6
50*5.6 = 280
Signal delay
Delay switch
difference [ns]
position
280-168 = 112
112/33 = 3.39 = 3
280-280 =
0
280-112 = 168
168/33 = 5.09 = 5
280-168 = 112
112/33 = 3.39 = 3
280-280 =
0
BOSCH Security Systems | February 2003
en |
17
0/33 = 0
0/33 = 0