Power Supply Installation

This chapter applies only to the Catalyst 2960-XR switches. It contains these topics:

Power Supply Module Overview

The switch operates with either one or two active power supply modules. You can use two AC modules, or
one module and a blank cover.
The Catalyst 2960XR-48FPD-I and 2960XR-48FPS-I only support the PWR-C2-1025WAC power supply.
Note
You cannot use the PWR-C2-250WAC and PWR-C2-640WAC power supplies in these switches.
Table 16: Power Supply Model Numbers and Description
Part Number
PWR-C2-250WAC=
PWR-C2-640WAC=
PWR-C2-1025WAC=
The 250-W and 640-W AC power supply modules are autoranging units that support input voltages between
100 and 240 VAC. The 1025-W power supply module is an autoranging unit that supports input voltages
between 115 and 240 VAC. All power supply modules have internal fans. All switches ship with a blank