Video Recorder 600 Series
6.6

System

6.6.1

Date/Time

Figure 6.18 System -Date/Time
1.
2.
3.
4.
5.
6.
6.6.2

NTP

The Time server function synchronizes the time of the unit with the time of a network time
server or another NTP-capable device. Choose either a Public Server to use a calibrated NTP
server on the Internet, or select a Private Server to set your own time source. Fill in the IP
address of the private network time server. Ensure that firewalls do not block NTP traffic via
UDP port 123.
1.
2.
6.6.3

Beeper

Select when the unit will Beep:
Bosch Security Systems
Enter the actual Date.
Fill in the actual Time.
Select a Date format which shows either the month (MM), the day (DD), or the year
(YYYY) first.
Select either a 12-hour or a 24-hour clock Time format.
Select a Time zone from the list (daylight saving time must be set manually).
Set Daylight Saving to On to enable it. Fill in the day, month, and time of both Start and
End time, and the Offset if it differs from the information associated with your time zone.
Press NTP Test to start time synchronization.
Set the Synchronization Interval to keep the unit closly matched with the time source.
Intervals can be as frequent as hourly, or as long as monthly.
On every Button press
When the unit is triggered by an Input, Motion, System failure, or Video loss.
Installation and Operation manual
Configuration menu | en
67
F.01U.169.663 | v1.0 | 2010.09