Specifications - Honeywell TrueSTEAM Operating Manual

Hide thumbs Also See for TrueSTEAM:
Table of Contents

Advertisement

Specifications

Install TrueSTEAM according to National Electric Codes.
Capacity:
HM512: 12 gallons per day (gpd) (45 liters per day [lpd])
HM509: 9 gpd (34 lpd)
HM506: 6 gpd (23 lpd)
Humidified Area:
House Description
Loose
Average
Tight
Weight:
Model
Empty
HM512
9 lbs.
HM509
9 lbs.
HM506
8 lbs.
Dimensions: 11-1/4 in. W x 19 in. H x 9 in. D
Humidifier Operating Temperature Range: 34ºF–104ºF (1.1ºC–40ºC)
Remote Hose/Nozzle Operating Temperature Range: -50ºF–250ºF (-46ºC–121ºC). Meet this spec-
ification if purchasing hose off-the-shelf.
Operating Humidity Range: 0–95% RH, non-condensing
Drain Hose Operating Temperature Range: 34ºF–212ºF (1.1ºC–100ºC)
Electrical Ratings and Tolerances
Input Ratings
• Power Supply: 120VAC +10/ -15%, 60Hz
- HM512: 1440W at 120VAC at full load
- HM509: 1200W at 120VAC at full load
- HM506: 840W at 120VAC at full load
• HM512: 12A, 120VAC
• HM509: 10A, 120VAC
• HM506: 7A, 120VAC
• 15A, 120VAC interlock switch
• Thermostat/HVAC power monitor (R to
C): 10mA resistive at 24VAC
• Field wiring terminals: 18–22 ga. solid
• HVAC power/airflow monitor: 10 mA
resistive at 24 VAC
Standards & Approval Body Requirements
Underwriters Laboratories: UL998, File no. E185662.
Federal Communications Commission: Class B compliance, File no. YU555.
Tested to ARI standard 610 and ASHRAE 62.2 for performance rating of central system humidi-
fier for residential applications. Intended to be used in accordance with the National Electrical
Code (NEC), ANSI/NFPA 70, and the rules of the Canadian Electrical Code (CEC), Part 1, C22.1.
Air Changes Per Hour
Two
One
One-half
Filled with Water
15 lbs.
14.5 lbs.
12 lbs.
TrueSTEAM Direct-Injection Humidifier
HM512
HM509
2000 sq. ft.
1300 sq. ft.
2500 sq. ft.
1800 sq. ft.
3000+ sq. ft.
2500 sq. ft.
Output Ratings
• Relay output contacts:
- Fan: 1.5A full load, 7.5A locked rotor
at 24VAC
- Heat and Backup: 15A resistive at
120VAC
• Fill Solenoid: 0.1A at 120VAC, 0.5 PF
• Drain Solenoid: 0.1A at 120VAC, 0.5PF
• Humidistat output contacts: 10mA
resistive at 24VAC
• Humidistat power supply: 100mA at
24VAC
5
HM506
1000 sq. ft.
1500 sq. ft.
2000 sq. ft.
69-2035EFS—0