What To Do If; Periodic Maintenance - AEG HG755440SM User Manual

Gas hob
Hide thumbs Also See for HG755440SM:
Table of Contents

Advertisement

Cleaning of the spark plug
This feature is obtained through a ceramic ignition candle with a metal electrode. Keep
these components well clean to prevent difficult lighting and check that the burner crown
holes are not obstructed.

Periodic maintenance

Periodically speak your local Service Force Centre to check the conditions of the gas supply
pipe and the pressure adjuster, if fitted.

WHAT TO DO IF...

Problem
There is no spark when lighting
the gas
The flame is blow out immedi-
ately after ignition
The gas ring burns unevenly
If there is a fault, first try to find a solution to the problem yourself. If you cannot find a
solution to the problem yourself, speak your dealer or the local Service Force Centre.
If you operated the appliance incorrectly, or the installation was not carried out by a regis-
tered engineer, the visit from the customer service technician or dealer may not take place
free of charge, even during the warranty period.
Possible cause
• There is no electrical supply
• Burner cap and crown are
placed uneven
• Thermocouple is not heated
sufficient
• Burner crown is blocked
with food residues
What to do if...
Remedy
• Make sure that the unit is
connected and the electrical
supply is switched on.
• Control the fuse. If the fuse
is released more than one
time, refer to a qualified
electrician.
• Make sure that the burner
cap and crown are in correct
positions.
• After lightning the flame,
keep the knob pushed for
approximately 5 seconds.
• Make sure that the injector
is not blocked and the burn-
er crown is clear of food
particles.
17