Panasonic KX-TDA100 Installation Manual page 145

Hybrid ip-pbx
Hide thumbs Also See for KX-TDA100:
Table of Contents

Advertisement

With KX-T7600 Series DPT (except KX-T7600E Series)
Using a Modular T-Adaptor
To DLC8/DLC16 card
To DHLC8 card
(for connection of SLT)
4-conductor wiring cord
Connect pins "D1" and
"D2".
Back View of DPTs
TO TEL
TO MAIN UNIT
/ PABX
Master DPT
Cable
ø 0.4 mm:
ø 0.5 mm:
ø 0.6 mm:
CAT 5:
Master DPT
To DLC8/DLC16 card
To DHLC8 card
(for connection of SLT)
2.7.3 Digital EXtra Device Port (Digital XDP) Connection
Modular
T-Adaptor
2-conductor wiring cord
Connect pins "T" and "R".
4-conductor wiring cord
Connect pins "D1" and "D2".
Slave DPT
Maximum Distance
30 m
50 m
60 m
50 m
Slave DPT
SLT
TO MAIN UNIT
/ PABX
Installation Manual
145

Advertisement

Table of Contents
loading

This manual is also suitable for:

Kx-tda200

Table of Contents