2.7.3 Digital EXtra Device Port (Digital XDP) Connection
Using an EXtra Device Port
To DLC8/DLC16 card
To DHLC8 card
(for connection of SLT)
4-conductor wiring cord
Connect pins "T", "R",
"D1" and "D2".
Back View of DPTs
TO TEL
TO MAIN UNIT
/ PABX
144
Installation Manual
Master DPT
Cable
ø 0.4 mm:
ø 0.5 mm:
ø 0.6 mm:
CAT 5:
Master DPT
To DLC8/DLC16 card
To DHLC8 card
(for connection of SLT)
4-conductor wiring cord
Connect pins "T", "R",
"D1" and "D2".
Slave DPT
Maximum Distance
30 m
50 m
60 m
50 m
Slave DPT
To SLT
2-conductor wiring cord
Connect pins "T" and "R".
SLT
TO MAIN UNIT
/ PABX
TO TEL