Service Information

To avoid risk of electrical shock, personal injury, or death, disconnect power to oven and discharge capacitor
before servicing, unless testing requires power.

Proper Handling of Magnetron Tubes

!
CAUTION
A magnetron tube, like a radio or television tube
must be handled with a reasonable amount of care.
When handling a tube, always handle by the housing
only. Use caution not to touch or strike the ceramic
portion at the top. The carton used to ship service
replacement tubes is reusable.

Magnetron Failure Modes

Magnetron failures that have been identified are
generally grouped into categories shown below.
1. Shorted
Air - This is a case where the tube has had the vacuum
envelope destroyed and air has entered the tube.
This will cause internal arcing and high secondary
current if high voltage is applied.
R.F. Capacitors - May short to chassis. This condition
will also cause loss of high voltage.
©2006 Maytag Services
!
W ARNING
2. Open Heater (Filament) - Can be determined by a
3. Low Power - Caused by "wearout" of the emission
4. Physical Damage - Caused by mishandling of
Output
Antenna
Ceramic
Fins
Magnet
16026795
ohmmeter when transformer leads are
disconnected. Resistance is normally less than one
ohm; filament does not short internally. Any tube
removed should be checked since usage tends to
make the filament more fragile. Later handling and
shipping may open the filament and thereby mask
the true failure mode when checked at the factory.
characteristics of the directly heated cathode.
Symptoms are: (1) tube current will take longer to
get to operating point than a new tube (normally
about 2 - 3 seconds), (2) tube current does not get
high enough to cause the tube to oscillate with
normal line voltage, (3) oven produces low power
into a load, two-thirds or less than normal.
magnetron tube.
Anode
Block
Terminals/R.F. Capacitors
Not Replaceable
Serial Number