Download Print this page

HP 2610 Series Specification page 40

Hp 2610 switch series
Hide thumbs Also See for HP 2610 Series:

Advertisement

QuickSpecs
Accessory Product Details
Physical
characteristics
Mounting
Environment
Electrical characteristics Description
Safety
Emissions
Immunity
DA - 13032 Worldwide — Version 18 — November 11, 2013
Dimensions
Weight
1U rack-mountable and wall-mountable enclosure using standard mounting
hardware
Operating temperature
Operating relative
humidity
Nonoperating/Storage
temperature
Nonoperating/Storage
relative humidity
Altitude
Acoustic
Voltage
Current
Maximum power rating
RPS power
PoE power
Frequency
Notes
CSA 22.2 No. 60950; EN 60950/IEC 60950; UL 60950
FCC Class A; VCCI Class A; EN 55022/CISPR 22 Class A
EN
ESD
Radiated
EFT/Burst
Surge
Conducted
Power frequency
magnetic field
Voltage dips and
interruptions
HP 2610 Switch Series
12.83(d) x 17.44(w) x 1.73(h) in. (32.59 x 44.3 x
4.39 cm) (1U height)
11.78 lb. (5.34 kg), Fully loaded
32°F to 131°F (0°C to 55°C)
15% to 95% @ 104°F (40°C), noncondensing
-40°F to 158°F (-40°C to 70°C)
15% to 95% @ 149°F (65°C), noncondensing
up to 15,000 ft. (4.6 km)
Noise emission LwA=59.2 dB at virtual workspace,
according to DIN 45635 T.19
The unit automatically adjusts to any voltage
between 100-240 V and either 50 or 60 Hz
100-240 VAC
9/5 A
800 W
180 W
408 W
50/60 Hz
Maximum power rating and maximum heat
dissipation are the worst-case theoretical
maximum numbers provided for planning the
infrastructure with fully loaded PoE (if equipped),
100% traffic, all ports plugged in, and all modules
populated.
EN 55024, CISPR 24
IEC 61000-4-2; 4 kV CD, 8 kV AD
IEC 61000-4-3; 3 V/m
IEC 61000-4-4; 1.0 kV (power line), 0.05 kV (signal
line)
IEC 61000-4-5; 1 kV/2 kV AC
IEC 61000-4-6; 3 V
IEC 61000-4-8; 1 A/m, 50 or 60 Hz
IEC 61000-4-11; >95% reduction, 0.5 period; 30%
reduction, 25 periods
Page 40

Advertisement

loading

This manual is also suitable for:

2610-48J9088a2610-24J9085aJ9087aJ9089a ... Show all