Motorola XR450 - RFID Reader - Contactless Integration Manual page 116

Xr series rfid readers
Table of Contents

Advertisement

B - 4
XR Series RFID Readers Integrator Guide
The green LED on the reader flashes while the update is in progress. The reader application software first
e.
downloads osupxr400.exe, FlashUpdateUtility.dll, and Response.txt files, starts running Osupdate, and
shuts itself down. Osupdate then downloads all the files specified in the Response.txt file into RAM, and if
the download is successful, starts writing the files to Flash. If the ftp is not successful for any reason, none
of the files will be written into Flash.
The update can take up to 15 minutes. Do not remove power to the reader or reboot the reader while
f.
update is in progress.
The reader reboots itself when the update is complete.
g.
If the reader had been set up with a static IP address, it restores the static IP address and reboots again.
h.
The reader could reboot a third time if the FPGA version has changed.
i.
NOTE During the FPGA update, all the LEDs will be turned OFF for about 90 seconds.
NOTE If there is a power outage during the upgrade, when the power comes back on, the Monitor program in
the reader retrieves all the files again using the TFTP server, and saves them on Flash.
Log onto the web console bring up the Version Control screen and verify that the new upgrade version is now
10.
running.