Table of contents

1
IMPORTANT SAFETY INSTRUCTIONS .................................................................7
2
INTRODUCTION.....................................................................................................10
3
DESCRIPTION........................................................................................................11
3.1
BLOCK DIAGRAM AND MAIN ELEMENTS..................................................................11
3.2
OPERATION MODES ...................................................................................................12
3.2.1 Normal operation mode .................................................................................................12
3.2.2 Utility failure operation ...................................................................................................12
3.2.3 Utility recovery operation ...............................................................................................13
3.2.4 Automatic Bypass..........................................................................................................13
3.2.5 Manual Bypass ..............................................................................................................13
3.3
PARALLEL SYSTEM OPERATION ..............................................................................14
3.3.1 Introduction to the parallel system.................................................................................14
3.3.2 Features of RPA parallel system ...................................................................................15
3.3.3 System control...............................................................................................................15
3.3.4 Synchronization .............................................................................................................15
3.3.5 Load sharing..................................................................................................................15
3.4
RECTIFIERS PARALLELED ON THE SAME BATTERY..............................................16
3.5
RECYCLING AT THE END OF SERVICE LIFE............................................................17
4
LAYOUT .................................................................................................................18
LAYOUT SG SERIES 10 AND 20 KVA ..............................................................................18
4.1
LAYOUT SG SERIES 30 AND 40 KVA ..............................................................................19
4.2
5
CONTROL PANEL .................................................................................................20
5.1
CONTROL PANEL ........................................................................................................20
5.2
6
LCD SCREEN.........................................................................................................22
6.1
METERING MODE........................................................................................................23
6.2
ALARMS........................................................................................................................26
6.3
PARAMETERS..............................................................................................................27
6.4
EDIT MODE ..................................................................................................................29
6.5
USER PARAMETERS...................................................................................................32
6.6
EVENTS (ALARMS AND MESSAGES) ........................................................................35
6.6.1 Alarms list ......................................................................................................................35
6.6.2 Messages list.................................................................................................................39
6.6.3 Event report SG Series .....................................................................................................41
7
OPERATION...........................................................................................................42
7.1
PROCEDURES FOR SINGLE UPS ..............................................................................43
7.1.1 Start-up of the SG Series ..................................................................................................43
7.1.2 Maintenance shutdown (Load on Q2) ...........................................................................44
7.1.3 From Manual Bypass (Q2) to normal function On-line ..................................................45
7.1.4 Complete UPS shutdown (No Load supply) ..................................................................46