GE Fanuc Automation
Programmable Control Products
VersaMax Serial to Ethernet Adapter
User's Manual
GFK-1852
July 2000

Advertisement

Table of Contents
loading

  Related Manuals for GE GFK-1852

  Summary of Contents for GE GFK-1852

  • Page 1 GE Fanuc Automation Programmable Control Products VersaMax Serial to Ethernet Adapter User's Manual GFK-1852 July 2000...
  • Page 2 Features may be described herein which are not present in all hardware and software systems. GE Fanuc Automation assumes no obligation of notice to holders of this document with respect to changes subsequently made.
  • Page 3 Technical Data: General ratings and specifications. Appendix A. IP Addresses: Format of IP addresses Appendix B. Binary to Hex Conversion: Conversion table Appendix C. Declaration of Conformity: Declaration of conformance to standards. Related Publications GFK-1645 VersaMax Micro PLCs and Nano PLCs User’s Manual GFK-1852 Preface...
  • Page 4: Table Of Contents

    Assigning a New IP Address... 4-3 Unix... 4-3 Configuration Parameters ... 4-4 SRTP/SNP Firmware – Configuration Setup ... 4-5 Network/IP Settings ... 4-5 IP Address... 4-6 Gateway IP Address ... 4-6 Netmask... 4-6 Channel, Serial, and Protocol Setups... 4-6 SRTP/SNP Protocol Mode... 4-6 GFK-1852 Contents...
  • Page 5 Modbus ID to IP Address Mapping ( only used for Master)... 4-19 Chapter 5 Monitor Mode and Firmware Upgrade... 5-1 Monitor Commands ... 5-1 Command result codes:... 5-2 Firmware Download Using Serial Port... 5-2 VersaMax Serial to Ethernet Adapter User's Manual–July 2000 GFK-1852...
  • Page 6 IC690ACC901 Miniconverter 9-Pin, Male D-Sub Connector ... 6-15 Chapter 7 Technical Data... 7-1 CPU, Memory, and Controllers... 7-1 Serial Interface ... 7-1 Network Interface... 7-1 Power Supply (not included)... 7-1 Power Consumption ... 7-1 Operating Temperature ... 7-1 GFK-1852 Contents Contents...
  • Page 7 IP Netmask ...A-2 Netmask Examples ...A-3 Private IP Networks and the Internet...A-3 Network RFC’s ...A-4 Appendix B Binary to Hexadecimal Conversion Table... B-1 Appendix C Declaration of Conformity ... C-1 viii VersaMax Serial to Ethernet Adapter User's Manual–July 2000 GFK-1852...
  • Page 8: Chapter 1 Introduction And Quick Start

    UDP for datagram applications). Various devices can be interfaced, for example: • PLCs • CNC Controllers • Terminals • Time/attendance and data collection devices • Industrial robots • Data display units • Instruments GFK-1852 Figure 1-1. IC200SET001 VMSE...
  • Page 9: Vmse Firmware Options

    CD that is shipped with the VMSE unit. Upgrades and new firmware choices will be placed on the GE Fanuc WEB site, as they become available. The VMSE ships with the default SRTP/SNP firmware loaded in flash memory.
  • Page 10: Quick Start

    The address pinged should reply as shown in the example in the next figure. In this example, the command and valid IP address was typed as follows: ping 3.16.16.14 GFK-1852 Chapter 1 Introduction and Quick Start Introduction and Quick Start...
  • Page 11 If the response is “No arp entries found,” repeat steps A. and B. to ping other devices until the arp -a command lists one or more devices. Note that the ARP table entries will be removed automatically after several minutes, so if you VersaMax Serial to Ethernet Adapter User's Manual – July 2000 GFK-1852...
  • Page 12 F. At the MS-DOS prompt, type Telnet (IP Address) 9999 (don’t forget the space between the IP address and 9999), and then press the Enter key This example uses: telnet 3.16.27.44 9999 GFK-1852 Chapter 1 Introduction and Quick Start Introduction and Quick Start...
  • Page 13 Enter key within 3 seconds, the telnet connection will time out and you will have to close the telnet window and repeat the previous step. Figure 1-6. The Telnet Response Window VersaMax Serial to Ethernet Adapter User's Manual – July 2000 GFK-1852...
  • Page 14 Figure 1-8. The “Connection to host lost” Telnet Box Click the OK button in the “Connection to host lost” Telnet dialog box to close it, and then close the Telnet box. GFK-1852 Chapter 1 Introduction and Quick Start Introduction and Quick Start...
  • Page 15 CD (see Chapter 5 for firmware upgrade details) before proceeding with configuration. Note that changing the firmware will not change the IP address set in the previous steps. VersaMax Serial to Ethernet Adapter User's Manual – July 2000 Note GFK-1852...
  • Page 16: Configuration

    – to revert to default settings • s – to save your changes and quit • q – to quit without saving your changes Figure 1-9. VMSE Configuration Screen GFK-1852 Chapter 1 Introduction and Quick Start Introduction and Quick Start Command Prompt...
  • Page 17: Configuration Example

    After each parameter value has been entered, the next parameter in order will appear at the prompt, as shown in the following figure: Figure 1-11. Continuing Configuration of the “CH1 Serial & Protocol Settings” 1-10 VersaMax Serial to Ethernet Adapter User's Manual – July 2000 GFK-1852...
  • Page 18 Modbus is a trademark of Gould, Inc. MS-DOS is a registered trademark of Microsoft, Inc. CIMPLICITY, Logicmaster, Series 90-30, Series 90-70, Series Six, VersaMax, and VersaPro, are trademarks of GE Fanuc NA. GFK-1852 Chapter 1 Introduction and Quick Start 1-11...
  • Page 19: Chapter 2 Vmse Interfaces

    NOTE: The VMSE is a single serial port device, meaning that only one port can be used at a time. In the configuration menu, Channel One refers to either one of the ports being used. Figure 2-1. VMSE Ports and Features GFK-1852...
  • Page 20: Network Interface

    24 Volt supply on the VersaMax, Series 90-30, or an external supply can be used. Take care not to exceed the capacity of the VersaMax or Series 90-30 power supply. VersaMax Serial to Ethernet Adapter User's Manual – July 2000 GFK-1852...
  • Page 21: Chapter 3 Network Protocols

    Every active device connected to the TCP/IP network must have a unique IP address. This IP address is used to reference a specific device, for example, to build a connection to the VMSE’s serial port. See Appendix A for a complete description of IP Addressing. GFK-1852...
  • Page 22: Port Number

    (port). The VMSE uses this port number for outgoing messages and incoming connections or UDP datagrams, which are addressed to its port number. Port 9999 (decimal) is used for remote configuration. VersaMax Serial to Ethernet Adapter User's Manual – July 2000 GFK-1852...
  • Page 23: Chapter 4 Configuration

    To enter configuration mode, the power on the VMSE must be cycled (powered off and back on). After power-up, the self-test begins. About a second later, three lowercase ‘x’ characters must be sent to the VMSE. These characters must all be sent within approximately one second to start the configuration mode. GFK-1852...
  • Page 24: Entering Network Configuration Mode

    As soon as a static IP address is assigned to the VMSE, the DHCP support will be disabled within the product. To re-enable DHCP support, the IP address should be set back to 0.0.0.0. VersaMax Serial to Ethernet Adapter User's Manual – July 2000 GFK-1852...
  • Page 25: Assigning A New Ip Address

    VMSE. Be sure to log into VMSE and store the parameters to make the IP address change permanent. Unix Unix arp details when the hardware address of the VMSE is 00-20-4A-01-64-0B. The command example for most Unix systems is: arp -s 191.12.3.77 00:20:4A:01:64:0B GFK-1852 Chapter 4 Configuration Configuration...
  • Page 26: Configuration Parameters

    If you need to load a different firmware than is in the VMSE, load the firmware first, and then follow the directions for configuration for the appropriate firmware. The next sections contain the details for configuration setup for each of the firmware loads. VersaMax Serial to Ethernet Adapter User's Manual – July 2000 GFK-1852...
  • Page 27: Srtp/Snp Firmware - Configuration Setup

    Press the “Q” key to exit without saving your changes. • Press the “D” key to return to the default settings. Network/IP Settings To change the Network/IP settings, press ‘1’. The following values can be set/changed: IP Address, Gateway Address, NetMask. GFK-1852 Chapter 4 Configuration Configuration...
  • Page 28: Ip Address

    SNP slave. For this usage set the SRTP/SNP mode to MODE#1 (Enter a “1”). This is what is used for VersaPro or HMI to communicate with a PLC by using a VMSE at the PLC. VersaMax Serial to Ethernet Adapter User's Manual – July 2000 GFK-1852...
  • Page 29: Serial Interface Configuration

    19200, D is the number of data bits (must be 8), P is parity (SNP defaults to O, the letter “O” not zero, S number of stop bits ( must be 1). The Default setting is the same as GE Fanuc PLC defaults; 19200 Baud, 8 data bits, Odd parity, and 1 stop bit.
  • Page 30: Passthru Firmware Configuration Setup

    Press the “7” key to activate the default settings. Basic Parameters To change the basic parameters (Server Configuration), press ‘0’. The following values can be set/changed: IP Address, Gateway Address, NetMask, and Telnet Password. VersaMax Serial to Ethernet Adapter User's Manual – July 2000 GFK-1852...
  • Page 31: Ip Address

    To change the Channel 1 configuration, press “1”. The following sections describe the item that can be changed and the values to use. Baud Rate The baud rate can be set within the defined limits from 300 to 38400 bits per second. GFK-1852 Chapter 4 Configuration...
  • Page 32: Interface Mode

    No flow control: XON/XOFF flow control in both directions: 01 Hardware handshake with RTS/CTS lines: 02 XON/XOFF, pass characters to host: 4-10 VersaMax Serial to Ethernet Adapter User's Manual – July 2000         GFK-1852...
  • Page 33: Port Number

    23 (this is the Internet standard port number for Telnet services). This port number is also used as the UDP destination port number for transmitted datagrams, provided the VMSE is used in UDP mode. GFK-1852 Chapter 4 Configuration 4-11...
  • Page 34: Connect Mode

    If manual connection startup is configured (with “C” + address/port), only the part not supplied in the command string is used. In manual mode, the last byte of the address must be supplied. 4-12 VersaMax Serial to Ethernet Adapter User's Manual – July 2000 GFK-1852...
  • Page 35: Datagram Mode

    Without a port number, this will make a connection to the remote port number defined within the VMSE. If no remote IP address and port number are defined within the VMSE, this command will force the VMSE into “monitor mode”. GFK-1852 Chapter 4 Configuration 4-13...
  • Page 36: Disconnect Mode

    With another bit in the disconnect mode, the VMSE can be forced into Telnet (terminal) mode and the setup for the terminal name can be enabled: - activate Telnet mode and terminal type setup: 4-14 VersaMax Serial to Ethernet Adapter User's Manual – July 2000 GFK-1852...
  • Page 37: Buffer Flushing

    Figure 4-6. Pack Control Options “Idle time to force transmit” defines the time period after which all accumulated characters are sent, regardless of the recognition of send characters. GFK-1852 Chapter 4 Configuration Configuration 7 6 5 4 3 2 1 0...
  • Page 38: Send Characters

    If the terminal type option is enabled, VMSE also reacts to the EOR (end of record) and binary options, which can be used for applications like terminal emulation to IBM hosts. 4-16 VersaMax Serial to Ethernet Adapter User's Manual – July 2000 GFK-1852...
  • Page 39: Modbus Tcp/Rtu Firmware Configuration Setup

    The IP address must be set to a unique value in your network. If you are not familiar with IP addresses, please refer to Appendix A. If the VMSE is given an address that is already in use it will not connect to the network. GFK-1852 Chapter 4 Configuration Configuration 4-17...
  • Page 40: Gateway Ip Address

    (default is 19200), D is the number of data bits , P is parity, S number of stop bits, and RSxxx is 232 or 485 . Modem Control Settings To change the Modem settings, press ‘3’. The following value can be set/changed: RTS Output 4-18 VersaMax Serial to Ethernet Adapter User's Manual – July 2000 GFK-1852...
  • Page 41: Advanced Modbus Protocol Settings

    Slave Addr/Unit ID , Modbus Serial Broadcasts, Character/Message Timeouts. Modbus ID to IP Address Mapping ( only used for Master) This setting is only available when Master is chosen. Entering “5” gives you the Mapping screen. GFK-1852 Chapter 4 Configuration 4-19...
  • Page 42: Monitor Mode And Firmware Upgrade

    All commands must be given in capital letters; only blanks (spaces) are accepted between parameters. Command SF x.x.x.x VS x.x.x.x GFK-1852 Description Download firmware to the VMSE Send firmware to VMSE with IP x.x.x.x Query software header record (16-byte)
  • Page 43: Command Result Codes

    VMSE serial number written twice. For example: SI194.39.78.234:146.138.146.138 IP address = 194.39.78.234 Remote VMSE serial # (146-138) = 146.138.146.138 NOTE: Since this is obtained by sending broadcast packets, this IP assignment cannot be done over the routers. Quit - exit diagnostics mode GFK-1852...
  • Page 44 After changing the firmware load in the VMSE, select defaults on the new firmware before setting the configuration to your desired settings; this keeps the VMSE from becoming confused. Figure 5-1. HyperTerminal Dialog Box GFK-1852 Chapter 5 Monitor Mode and Firmware Upgrade...
  • Page 45: Firmware Distribution

    Enter key. See the example in the figure and following explanation: Figure 5-2. Using TFTP in Windows NT to store files to the VMSE The figure above shows a successful store to the VMSE at IP address 3.16.27.40. VersaMax Serial to Ethernet Adapter User's Manual – July 2000 GFK-1852...
  • Page 46: Windows Nt Command Line Example Code Explanation

    For example, if you are downloading PassThru into a new unit which has the default software of SNP/SRTP, you would enter a destination of G1. Note: The destination is case sensitive. The letter “G” in this example must be upper case. GFK-1852 Chapter 5 Monitor Mode and Firmware Upgrade Monitor Mode and Firmware Upgrade...
  • Page 47: Windows 95/98 Procedure

    “BANDWIDTH KILLER” version (either the .exe or .zip version).  PumpKIN software is copywrited 1997, 1998 by Klever Group, Inc.  Windows is a registered trademark of Microsoft, Inc. VersaMax Serial to Ethernet Adapter User's Manual – July 2000 GFK-1852...
  • Page 48: Chapter 6 Serial Line Interfaces

    To VMSE Hard-Wired Output Not Connected Figure 6-1. Serial RJ-45 (RS-232) Pin-out Configuration NOTE: Pin number 1 of the RJ-45 serial connector is the first pin from the top. GFK-1852 Function None RTS Ready to Send CTS Clear to Send...
  • Page 49: Screw Block Connector Pin-Outs And Other Components

    The next figure and following table illustrate and describe the screw block connector pin-outs, LED operation, and other features of the VMSE. Figure 6-2. Front Panel Layout VersaMax Serial to Ethernet Adapter User's Manual – July 2000 Pin 1 GFK-1852...
  • Page 50 For RS-485 2-wire functionality, pins 1 & 4 and 2 & 3 of the screw terminals must be connected together. • The RJ-45 Ethernet connector uses industry standard 10Base T connections. GFK-1852 Chapter 6 Serial Line Interfaces Serial Line Interfaces Purpose...
  • Page 51: Cable Diagrams

    Nano/Micro PLC Connector (RJ45) IC200CBL504 Marking denotes PLC end 10cm (4 inches) VMSE Connector PLC Connector 4 - TXD RXD - 6 3 - RXD TXD - 5 8 – Sig. Gnd. Sig. Gnd.- 4 To PLC Pin 1 GFK-1852...
  • Page 52: User-Built Cable #1: Vmse Rj45 Serial To Miniconverter

    User-Built Cable #1: VMSE RJ45 Serial to Miniconverter This cable is not currently sold by GE Fanuc. Details are provided so you can build your own cable. Application: To connect a VMSE’s RJ-45 Serial port (RS-232) to the RS-232 port of an IC690ACC901 Miniconverter (RS-232 to RS422/485).
  • Page 53: User-Built Cable #2: Vmse Rj45 Serial To Pc 9-Pin Sub-D

    User-Built Cable #2: VMSE RJ45 Serial to PC 9-Pin Sub-D This cable is not currently sold by GE Fanuc. Details are provides so you can build your own cable. Application: To connect a personal computer’s RS-232 serial port to a VMSE’s RJ-45 Serial port for the purpose of (1) monitoring VMSE operation or (2) downloading firmware to the VMSE.
  • Page 54: User-Built Cable #3: Vmse Rj45 Serial To Pc 9-Pin D-Sub

    User-Built Cable #3: VMSE RJ45 Serial to PC 9-pin D-Sub This cable is not currently sold by GE Fanuc. Details are provides so you can build your own cable. Application: To connect the serial port (RS-232) of a personal computer (PC) running VersaPro software to a VMSE’s RJ-45 Serial port (RS-232).
  • Page 55: User-Built Cable #4: Vmse Rs-422 Terminals To Plc

    User-Built Cable #4: VMSE RS-422 Terminals to PLC This cable is not currently sold by GE Fanuc. Details are provides so you can build your own cable. Application: Connects the VMSE terminal block screw terminals to a PLC 15-pin, D-sub, RS- 422/RS-485 port such as is used on Series 90-30, Series 90-70, and VeraMax PLCs.
  • Page 56: Using The Vmse On An Rs-422/485 Multidrop Network

    Each serial cable’s shield must be grounded at one end of the cable only. • The VMSE can be the only device connected to the master on Serial Line 1 shown in Figure 6-14 above. GFK-1852 Chapter 6 Serial Line Interfaces Serial Line Interfaces Slave #1...
  • Page 57: Serial Port Connectors

    VersaMax Serial to Ethernet Adapter User's Manual – July 2000 IBM-AT D-Sub, Male, 9-Pin Pin 6 Pin 1 External View Signal Description Data Carrier Detect Receive Data Transmit Data Data Terminal Ready Signal Ground No Connection Request to Send Clear to Send No Connection GFK-1852...
  • Page 58: 9-Pin, D-Sub Plc Serial Port Connector

    VersaMax serial ports, please refer to the VersaMax PLC User’s Manual, GFK-1503. Signal Shell SHLD Figure 6-16. 9-Pin D-Sub Serial Port Connector GFK-1852 Chapter 6 Serial Line Interfaces Serial Line Interfaces Pin-Out for 9-Pin D-Sub Serial Connector (RS-432) Direction Function...
  • Page 59: 15-Pin, D-Sub Plc Serial Port Connector

    Resistor Termination (120 ohm) for RDA’ Input Receive Data (A) input Input Receive Data (B) input Output Transmit Data (A) output Output Transmit Data (B) output Output Request to Send (B) output Input Clear to Send (A) input Cable Shield wire connection GFK-1852...
  • Page 60: Rj-11 Plc Serial Port Connector

    70 CPUs. For additional information on these ports, please refer to the Series 90 PLC Serial Communications Manual, GFK-0582. Pin 1 Number Figure 6-18. RJ-11 Serial Port Connector GFK-1852 Chapter 6 Serial Line Interfaces Serial Line Interfaces RS-232, 6-Pin RJ-11 External View...
  • Page 61: Rj-45 Versamax Nano/Micro Plc Serial Port Connector

    RS-232, 8-Pin RJ-45 Pin 1 External View Function Request to Send output Clear to Send input Receive Data input Transmit Data output Data Carrier Detect input Data Terminal Ready output +5VDC output to power external converters 0V/Gnd signal reference GFK-1852...
  • Page 62: Ic690Acc901 Miniconverter 9-Pin, Male D-Sub Connector

    Refer to the Series 90-30 PLC Hardware and Installation Manual, GFK- 0356, for a data sheet on the IC690ACC901 Miniconverter. Pin-Out for 9-Pin D-Sub Male Miniconverter Serial Connector (RS-432) Signal Figure 6-20. IC690ACC901 Miniconverter RS-232 Connector Pin-Out GFK-1852 Chapter 6 Serial Line Interfaces Serial Line Interfaces Direction Function...
  • Page 63: Chapter 7 Technical Data

    Switch selectable RS-232C or RS-422/485 – screw terminal connector only Network Interface • Integrated 10BaseT port (RJ-45 connector) Power Supply (not included) • Screw terminals for 9-30 Volt DC input from external supply Power Consumption • Maximum 3 Watt Operating Temperature • 0-60 degrees C (32-140 degrees F) GFK-1852...
  • Page 64: Leds

    Two LEDs for serial channel status. Case • Plastic case for DIN rail mounting Dimensions Weight • Approx. 150g (0.33 lb) VersaMax Serial to Ethernet Adapter User's Manual – July 2000 Depth = 36mm (1.42”) 90mm (3.54”) 60mm (2.36”) GFK-1852...
  • Page 65: Appendix A Ip Addresses

    (up to 16,777,216) Example: 10.0.0.1, (network 10, host 0.0.1) Class B Network IP address 128.0.x.x to 191.255.xxx.xxx These networks are used for large company networks. Every network can consist of up to 65,534 devices. Example: 172.1.3.2 (network 172.1, host 3.2) GFK-1852...
  • Page 66: Class C Network

    When the number of host bits is entered, the VMSE calculates the netmask. The netmask is displayed in standard decimal-dot notation. Network Bits Class A Class B Class C Figure A-1. Standard IP Network Netmask VersaMax Serial to Ethernet Adapter User's Manual – July 2000 Host Bits Netmask 255.0.0.0 255.255.0.0 255.255.255.0 GFK-1852...
  • Page 67: Netmask Examples

    Intranet you should use one of the sub-networks below. These network numbers have been reserved for such networks. If you have any questions about IP assignment consult your Network Administrator. Class A Class B Class C GFK-1852 Appendix A IP Addresses IP Addresses Host bits 10.x.x.x 172.16.x.x...
  • Page 68: Network Rfc's

    World Wide Web using one of the directories or indices: RFC 950 Internet Standard Subnetting Procedure RFC 1700 Assigned Numbers RFC 1117 Internet Numbers RFC 1597 Address Allocation for Private Internets VersaMax Serial to Ethernet Adapter User's Manual – July 2000 GFK-1852...
  • Page 69: Appendix B Binary To Hexadecimal Conversion Table

    2F0. First separate the binary number into groups of four bits (add two leading zeroes): 0010 1111 0000. Then use the above conversion table to find the hexadecimal value for each group: 0010 = 2, 1111 = F, 0000 = 0. GFK-1852 Binary Hexadecimal...
  • Page 70: Appendix C Declaration Of Conformity

    This product has been verified as being compliant within the class A limits of the FCC Radio Frequency Devices Rules (FCC Part 15, Subpart B), revised as of October 1993. "The product complies with the requirements of the Low Voltage Directive 73/23/EEC and the EMC Directive 89/336/E GFK-1852 VMSE IC200SET001 C1SPR22: 1993 Class “A”...
  • Page 71 7-1 Datagram mode, 4-13 DHCP, 4-2 Diagrams cable, 6-4 front panel layout, 6-2 Dimensions, 7-2 Disconnect mode GFK-1852 Index DTR disconnect, 4-14 Ethernet, 2-2 External transceiver, 2-2 Firmware download from VMSE to VMSE, 5-4 download via network host, 5-4...
  • Page 72 Private IP networks, A-3 Remote configuration, 3-2 Remote IP address, 4-11 Remote TCP port, 4-11 RJ-11 connector pin-out, 6-13 RS-232 selecting, 2-1 VMSE RJ45 connector, 6-1 RS-422 cable, 6-8 multidrop, 6-9 RS-485 selecting, 2-1 Screw block connector pin-outs, 6-2 Send characters GFK-1852...
  • Page 73 4-11 TCP/IP, 3-1, 4-2 Telnet, 3-1, 3-2, 4-1, 4-3 configuration, 4-9 force mode, 4-14 standard port no., 4-11 terminal type, 4-16 Temperature GFK-1852 Index Index operating range, 7-1 Timeout, inactivity, 4-15 UDP, 3-1 datagram mode, 4-11 destination port no., 4-11...

This manual is also suitable for:

Versamax ic200set001