DIAGNOSTIC STATUS CODES
SX TRANSISTOR CONTROL
TRACTION
STATUS CODE
The armature current exceeds the
-67
armature transistor limit.
MEMORY RECALL
YES
SYMPTOM
Control will not operate.
Circuits valid
for
POSSIBLE CAUSE
= Shorted motor armature A1 to A2
Traction
= Power cables may be shorted to each other
Controller
(Measure at control terminals)
= A1 to A2 terminals may be shorted to battery
positive or negative
DESCRIPTION OF STATUS
CORRECTIVE ACTIONS
CAUSE OF STATUS INDICATION
This status code will be displayed when the armature
transistor exceeds its specific current limit. The
control is reset by recycling the key switch.
TROUBLE-SHOOTING DIAGRAM
FU5
KEY SWITCH
P2
SP
P5
TO
ACCESSORIES
P4
FU6
P3
PY7
PY12
P18
P17
P1
OSCILLATOR CARD
PY10
LEFT CONTROL
PY11
FU1
LINE
FU2
FU4
+
A1
P
A1
F1
POS
POWER
-
CONNECTIONS
SP
LEFT CONTROL
NEG
A2
F2
SP
P
Page 37
BRAKE SW.
P1
L
P4
P2 P6
P3
P5
P7
P10
P9
P12 P8
STEER
ANGLE
ACC POT
BDI INTERRUPT
POS
A1
F1
POWER
CONNECTIONS
RIGHT CONTROL
A2
NEG
F2
January 2000