Viewing Available Storage Systems - HP 3PAR StoreServ 7200 2-node Manual

Hp 3par-to-3par storage peer motion guide (os 3.1.2 mu2) (ql226-97008, june 2013)
Hide thumbs Also See for 3PAR StoreServ 7200 2-node:
Table of Contents

Advertisement

Group
Fibre Channel
Settings
(displayed for
FC and RCFC
ports)
iSNS Settings
(displayed for
iSCSI ports -
not shown)

Viewing Available Storage Systems

The Available Storage tree node list the names of all available storage systems that can be used
for data migration and provides summary information in the Management Window.
The following information is displayed for each available system. Clicking a system name displays,
on separate subtabs, available storage system summary information and alerts that are associated
with the system. For information on the separate subtabs, see
Field
Description
Gateway
The address of a local IP router on the same network as the system, used to forward
traffic to destinations beyond the local network.
Subnet Mask
The netmask address for the iSCSI or RCIP interface.
MTU
The greatest amount of data or "packet" size that can be transferred at one time
over a particular network connection without overburdening the connection. The
default MTU setting for an iSCSI port is 1500. When supported by the network,
an MTU value of 9000 should be used.
Configured Rate
For RCIP ports. The configured data transfer rate. A value of 0 indicates that no
data is being transferred.
Rate
For iSCSI ports. Data transfer rate. A value of 0 indicates that no data is being
transferred.
TCP Port
The TCP port number used by the iSCSI card.
Duplex
For RCIP ports. The duplex speed: Half or Full.
Adapter Type
For RCIP ports, the model of the adapter that contains the port (for example, Intel
PRO/1000MT).
Topology
The type of connection (for example, Fabric Attached).
Class
Identifies which Fibre Channel classes of service are enabled (2, 3, or 2/3). A
value of 2/3 indicates that both Class 2 and Class 3 are enabled.
Adaptor Type
Model of the Fibre Channel adapter that contains the port (such as QLOGIC
2302).
Mode Change
Indicates whether port mode change from initiator to target or vice versa is Allowed
or Prohibited. This setting is configured using the CLI controlport command.
Primary IP Address
Primary Internet Storage Name Service (iSNS) server IP address. iSNS protocol
allows for automated discovery, management, and configuration of iSCSI.
TCP Port
The port on the iSNS server with which to communicate.
"Viewing Source and Destination
Viewing Available Storage Systems
51

Advertisement

Table of Contents
loading

Table of Contents