Booting from the CLI

To activate a partition from the command line, you can either use the poweron partition
{identifier} command, the bo command, or the pe command.
poweron partition 2
Poweron request sent to partition 2. Operation initiated successfully.
Please run PARSTATUS/VPARSTATUS or SHOW SYSLOG OA to determine the completion
status of the operation.
After you power on the nPartition, the partition firmware is booted and comes up to the Active/EFI
state if the nPartition is in nPars mode or to Active/RUN_VPARS state if the nPartition is in vPars
mode.
parstatus -P
[Partition]
Par State/
Num RunState
=== ======================= ======= ====== ====== ============= ===============
1
Inactive /DOWN
2
Active /RUN_VPARS
3
Active /EFI
4
Inactive /DOWN
5
Inactive /DOWN
*
D-Degraded
** Actual allocated for Active and User requested for Inactive partitions
Status* # of
# of
Blades IOBays SLM
OK
1
0
OK
2
2
OK
1
2
OK
0
0
OK
0
0
Booting to UEFI and preparing for Operating System installation
ILM/
Partition Name
(first 15
(GB)**
characters)
0.0/0.0
nPar0001
2.0/28.0
nPar0002
2.0/28.0
hard_partition
0.0/0.0
nPar0004
0.0/0.0
nPar0005