Cee Switch Management Using Telnet; Virtual Fcoe Port Configuration - HP Brocade BladeSystem 4/12 User Manual

Dcfm professional user manual (53-1001773-01, june 2010
Hide thumbs Also See for Brocade BladeSystem 4/12:
Table of Contents

Advertisement

13

CEE switch management using Telnet

CEE switch management using Telnet
You can use Telnet to log in and issue command line-based commands to a CEE switch.
To launch a Telnet session, complete the following steps:
1. Launch the CEE Configuration dialog box using one of the following methods:
2. Select the CEE switch.
3. Click Telnet.

Virtual FCoE port configuration

The virtual FCoE port has the following configuration features:
336
Select Configure > Switch > CEE from the menu bar.
Right-click the CEE switch from the device tree, and select Configure > CEE.
Right-click the CEE switch from the topology map and select Configure > CEE.
The CEE Configuration dialog box displays, showing the status of all CEE-related hardware and
functions.
The Telnet session window displays.
NOTE
On Linux systems, you must use CTRL + BACKSPACE to delete text in the Telnet session
window.
Eight 10-Gbps CEE ports, which can be enabled for FCoE traffic.
One-to-one mapping of FCoE ports with 10 Gbps Ethernet ports.
Eight 8 Gbps FC ports.
24 internal FCoE ports, which provide the Ethernet-to-FC bridging capability. You can enable or
disable each FCoE trunk individually.
Each of the FCoE ports can be configured as an E_Port or an F_Port.