Table 7 HP Network Advisor 1 1.1.0 closed defects (continued)
Closed fixes summary
Remote VE_Port WWN is shown as missing and with a red icon under end
devices.
Fault Management – "VFID" is shown as "Chassis" for "Switch name change
event" in the master log.
There are yellow dotted lines shown between the segmented switch and
the End Device in the re-discovered fabric.
In the Client, IFL/ISL connections are not being displayed correctly in the
topology view when multiple circuits are added with different GigE ports
for a tunnel.
For zoning, sorting of ports is not accurate in the Hex display mode for the
user port number.
In the Client, the latest topology changes are not reflected; the yellow dotted
line is not shown when the tunnel is deleted.
In the Device Tree, on selecting an E_Port on switch1, after 1 minute focus
changes to the same port under switch-2, and is misleading to the user.
When a user attempts to delete a logical switch the operation may fail with
the error message internal server error.
A user is unable to edit the commit rate of a second circuit after the first
circuit has been modified without closing and reopening the FCIP Tunnel
dialog box.
In the Client, the Logical Switch Sequence Number is displayed incorrectly
in the Switch Properties Dialog.
In Port Fencing, Switch-level Alert was missing when a port is fenced for
Link reset violation type.
FCIP Circuits do not come up and stay in an 'In progress' state after
changing the commit rate.
At times hosts are not displayed and a user will not be able to view the
LUNs configured for a container.
Syslog registration fails for HP StorageWorks 4/32B SAN Switches with
a McDATA OUI 08:00:88
Encryption HAC Failover status not displayed.
Decommissioning a LUN in an Encryption Group (EG) that is configured
with TKLM returns an error message that is invisible to the user.
Unable to discover fabric in DCFM if IP address of any member switch is
0.0.0.0.
A user is unable to invoke the patch install dialog from DCFM 10.4.3 when
logged in as a user with admin privileges.
Solution
Fixed in HP Network Advisor 1 1.1.0.
Fixed in HP Network Advisor 1 1.1.0.
Fixed in HP Network Advisor 1 1.1.0.
Fixed in HP Network Advisor 1 1.1.0.
Fixed in HP Network Advisor 1 1.1.0.
Fixed in HP Network Advisor 1 1.1.0.
Fixed in HP Network Advisor 1 1.1.0.
Fixed in HP Network Advisor 1 1.1.0.
Workaround prior to upgrade: Close and
reopen the circuit dialog on different
circuits to perform the edit operation.
Fixed in HP Network Advisor 1 1.1.0.
Fixed in HP Network Advisor 1 1.1.0.
Fixed in HP Network Advisor 1 1.1.0.
Workaround prior to upgrade: Change
commit rates on both the local and remote
ends separately through the CLI if there
are different VLAN tags at both ends.
Fixed in HP Network Advisor 1 1.1.0.
Workaround prior to upgrade: Hit the
refresh button in the target dialog to see
the hosts configured.
Fixed in HP Network Advisor 1 1.1.0.
Workaround prior to upgrade: Add syslog
registration via the CLI.
Fixed in HP Network Advisor 1 1.1.0.
Fixed in HP Network Advisor 1 1.1.0.
Fixed in HP Network Advisor 1 1.1.0.
Workaround prior to upgrade: Configure
valid IP addresses for all switches in the
fabric.
Fixed in HP Network Advisor 1 1.1.0.
Workaround prior to upgrade: Login as
system administrator.
Fixed in HP Network Advisor 1 1.1.0.
Migration and upgrades