Verifying The Configurations - HP 6125XLG Configuration Manual

Blade switch fcoe configuration guide
Table of Contents

Advertisement

[SwitchA-Vfc1] fc mode f
[SwitchA-Vfc1] quit
[SwitchA] interface vfc 2
[SwitchA-Vfc2] fc mode f
[SwitchA-Vfc2] quit
Configuring Switch B
# Configure Switch B to operate in advanced mode, save the configuration, and reboot Switch B. (Skip
this step if the switch is operating in advanced mode.)
<SwitchB> system-view
[SwitchB] system-working-mode advance
Do you want to change the system working mode? [Y/N]:y
The system working mode is changed, please save the configuration and reboot the
system to make it effective.
# Configure Switch B to operate in NPV mode. Create VSAN 1.
<SwitchB> system-view
[SwitchB] fcoe-mode npv
[SwitchB] vsan 1
[SwitchB-vsan1] quit
# Create interface VFC 3, and configure it to operate in F mode.
[SwitchB] interface vfc 3
[SwitchB-Vfc3] fc mode f
# Bind interface VFC 3 to interface Ten-GigabitEthernet 1/1/7, and assign it to VSAN 1 as a trunk port.
[SwitchB-Vfc3] bind interface ten-gigabitethernet 1/1/7
[SwitchB-Vfc3] port trunk vsan 1
[SwitchB-Vfc3] quit
# Configure Ten-GigabitEthernet 1/1/7 to allow VLAN 10.
[SwitchB] interface ten-gigabitethernet 1/1/7
[SwitchB-Ten-GigabitEthernet1/1/7] port link-type trunk
[SwitchB-Ten-GigabitEthernet1/1/7] port trunk permit vlan 10
[SwitchB-Ten-GigabitEthernet1/1/7] quit
# Enable FCoE for VLAN 10 and map VLAN 10 to VSAN 1.
[SwitchB] vlan 10
[SwitchB-vlan10] fcoe enable vsan 1
[SwitchB-vlan10] quit

Verifying the configurations

# Display the nodes on downlink interfaces and their mapped uplink interfaces.
[SwitchA] display npv login
Server
Interface VSAN FCID
Vfc1
Vfc2
# Display the status of Switch A.
[SwitchA] display npv status
Port WWN
1
0x010001 20:00:00:15:40:94:00:00 20:00:00:15:40:94:00:00 Vfc3
1
0x010002 20:00:00:42:40:94:00:01 20:00:00:42:40:94:00:01 Vfc3
Node WWN
93
External
Interface

Advertisement

Table of Contents