Download Print this page

HP 6125XLG Configuration Manual: Verifying The Configurations

R2306-hp 6125xlg blade switch fcoe configuration guide.
Hide thumbs

Advertisement

# Assign interface Ten-GigabitEthernet 1/1/6 to VLAN 10 as a trunk port.
[SwitchD] interface ten-gigabitethernet 1/1/6
[SwitchD-Ten-GigabitEthernet1/1/6] port link-type trunk
[SwitchD-Ten-GigabitEthernet1/1/6] port trunk permit vlan 10
[SwitchD-Ten-GigabitEthernet1/1/6] quit
# Enable FCoE for VLAN 10 and map VLAN 10 to VSAN 1.
[SwitchD] vlan 10
[SwitchD-vlan10] fcoe enable vsan 1
[SwitchD-vlan10] quit

Verifying the configurations

# Display the domain information of VSAN 1 on Switch A.
[SwitchA] display fc domain vsan 1
Domain Information of VSAN 1:
Running time information:
State: Stable
Switch WWN: 48:33:43:2d:46:43:1A:1A
Fabric name: 48:33:43:2d:46:43:1B:1B
Priority: 128
Domain ID: 11
Configuration information:
Domain configure: Enabled
Domain auto-reconfigure: Disabled
Fabric name: 48:33:43:2d:46:43:1A:1A
Priority: 128
Domain ID: 11 (preferred)
Principal switch running time information:
Priority: 1
Path
Upstream
Downstream
The output shows that the domain configuration is complete and that the principal switch assigns domain
ID 1 1 to Switch A.
# Display the domain ID list of VSAN 1 on Switch A.
[SwitchA] display fc domain-list vsan 1
Domain list of VSAN 1:
Number of domains: 4
Domain ID
0x01(1)
0x0b(11)
0x0d(13)
0x0e(14)
Interface
Vfc1
Vfc2
WWN
48:33:43:2d:46:43:1B:1B [Principal]
48:33:43:2d:46:43:1A:1A [Local]
48:33:43:2d:46:43:1C:1C
48:33:43:2d:46:43:1D:1D
45

Advertisement