[SwitchB-Ten-GigabitEthernet1/1/5] quit
# Create interface VFC 1, configure it to operate in F mode, bind it to interface
Ten-GigabitEthernet 1/1/5, and assign it to VSAN 1 as a trunk port.
[SwitchB] interface vfc 1
[SwitchB-Vfc1] fc mode f
[SwitchB-Vfc1] bind interface ten-gigabitethernet 1/1/5
[SwitchB-Vfc1] port trunk vsan 1
[SwitchB-Vfc1] quit
# Assign interface Ten-GigabitEthernet 1/1/5 to VLAN 10 as a trunk port.
[SwitchB] interface ten-gigabitethernet 1/1/5
[SwitchB-Ten-GigabitEthernet1/1/5] port link-type trunk
[SwitchB-Ten-GigabitEthernet1/1/5] port trunk permit vlan 10
[SwitchB-Ten-GigabitEthernet1/1/5] quit
# Create interface VFC 2, and configure it to operate in E mode.
[SwitchB] interface vfc 2
[SwitchB-Vfc2] fc mode e
# Bind interface VFC 2 to interface Ten-GigabitEthernet 1/1/6, and assign it to VSAN 1 as a trunk
port.
[SwitchB-Vfc2] bind interface ten-gigabitethernet 1/1/6
[SwitchB-Vfc2] port trunk vsan 1
[SwitchB-Vfc2] quit
# Assign interface Ten-GigabitEthernet 1/1/6 to VLAN 10 as a trunk port.
[SwitchB] interface ten-gigabitethernet 1/1/6
[SwitchB-Ten-GigabitEthernet1/1/6] port link-type trunk
[SwitchB-Ten-GigabitEthernet1/1/6] port trunk permit vlan 10
[SwitchB-Ten-GigabitEthernet1/1/6] quit
# Enable FCoE for VLAN 10 and map VLAN 10 to VSAN 1.
[SwitchB] vlan 10
[SwitchB-vlan10] fcoe enable vsan 1
[SwitchB-vlan10] quit

Verifying the configurations

1.
Verify the configurations on Switch A.
[SwitchA] display fc domain vsan 1
Domain Information of VSAN 1:
Running time information:
Configuration information:
State: Stable
Switch WWN: 48:33:43:2d:46:43:1A:1A
Fabric name: 11:11:11:11:11:11:11:11
Priority: 128
Domain ID: 1
Domain configure: Disabled
Domain auto-reconfigure: Disabled
Fabric name: 11:11:11:11:11:11:11:11