Before connecting power to the converters, change the fuse and voltage selector to the appropriate The MI715 converts incoming analog signals to 24-bit MADI 220/230/240 VAC settings. digital signals that capture the input’s complete dynamic range. Each main AES/EBU input is automatically evaluated The converters preserve their signal quality using linear power for sample-rate conversion.
Knowledge Base or join the worldwide Avid user community on the User Conference. This guide provides a basic overview of MI715 and MO705 features and functionality. Training and Education Study on your own using courses avail-...
Sample Rate Source can be auto-sensed or manually se- lected. If an external source is not detected, the MI715 reverts In addition to their standard use in a digital system, the MI715 to Internal sync; the MO705 mutes its outputs. If a manually and MO705 can be used as stand-alone converters.
MI715 Back Panel MI715 back panel Input Voltage Selector This red switch allows the unit to oper- Parallel AES/EBU Digital Inputs (female DB25) Two 8-channel ate in either 110/115 VAC or 220/230/240 VAC environ- digital connectors function in parallel with XLR digital inputs, ments.
MI715 Power Connector (IEC) and Fuse Tray The IEC power connec- The MI715 Sample Rate is set externally by one of two source tor accepts standard IEC power cords. The fuse tray contains signals or internally by crystals and associated circuitry. The...
Appendix A: Specifications MI715 Performance Specifications Sync Sources AES, word clock, internal Sync Outputs AES thru and word clock out Sync Detection Auto or switched Internal Sample Rate 44.1, 48, 88.2, 96 kHz ±50 ppm Lock range 300 ppm fine mode 12% varispeed of 44.1 and 48 kHz...
Page 12
TPDF (active only for 16- or 20-bit word length) Digital Format Pro or Consumer, internally switched μ s @ 48 kHz) Group Delay AES (XLR), transformer isolated, 110 S/PDIF (RCA), 75 Digital Format professional or consumer (internally switched) MI715/MO705 Guide...
Page 13
MI715/MO705 Technical Specifications Power Requirements 110/115 VAC or 220/230/240 VAC; 50 or 60 Hz Power Consumption 50 W Temperature of Operation 5–35 Dimensions Height: 3.5 in; Width: 19 in; Depth: 18.25 in; Weight: 17 lb Appendix A: Specifications 9...
Appendix B: Compliance Information Proposition 65 Warning Environmental Compliance This product contains chemicals, including lead, Disposal of Waste Equipment by Users in the known to the State of California to cause cancer European Union and birth defects or other reproductive harm. Wash hands after handling.
Avid is authorized to apply the CE (Conformité Europénne) mark on this compliant equipment thereby declaring conformity to EMC Directive 2004/108/EC and Low Any modifications to the unit, unless expressly approved by Voltage Directive 2006/95/EC. Avid, could void the user's authority to operate the equipment. MI715/MO705 Guide...
13) Unplug this equipment during lightning storms or when unused for long Safety Compliance periods of time. 14) Refer all servicing to qualified service personnel. Servicing is required when the equipment has been damaged in any way, such as power-supply cord or plug Safety Statement is damaged, liquid has been spilled or objects have fallen into the equipment, the equipment has been exposed to rain or moisture, does not operate normally,...