Adjusting the response time (beam blocking volume)
You can use the response time adjustable volume to adjust the time between 50ms and 700ms.
Where an intruder can move across an area quickly, adjust the settings to 50ms; in a fence where unauthorized access is slow,
adjust the settings to 700ms.
Full-speed run – 50 msec
Fast walk – 150 msec
Normal walk – 250 msec
Slow walk – 550 msec
Jump over a fence or obstacle – 700 msec

Alarm Memory

Turn on the DIP switch #4 of the receiver to activate the alarm memory function.
If an alarm occurs, the detector will blink for 55 minutes after 5 minutes of standby. This can inform the patrol-guard that the
sensor has been activated when they arrive on site.
Alarm occurrence
Memory LED
M
Z6806119901A-SIA-0100Q,0200Q.ind11 11
Z6806119901A-SIA-0100Q,0200Q.ind11 11
60 min (restart operation)
5 min
55 min (blinking)
English _11
5 min
2010-03-30 오전 12:18:38
2010-03-30 오전 12:18:38