Description
Maximum heat
dissipation
Voltage
Current
Idle power
Maximum power rating
Frequency
Notes
EN 60950/IEC 60950; CAN/CSA 22.2 No. 60950; EN 60825; UL 60950
FCC part 15 Class A; EN 55022/CISPR-22 Class A; VCCI Class A
EN
ESD
Radiated
EFT/Burst
Surge
Conducted
Power frequency
magnetic field
Voltage dips and
interruptions
Harmonics
Flicker
HP PCM+; HP PCM; command-line interface; Web browser; out-of-band management (serial RS-232C)
When using mini-GBICs with this product, mini-GBICs with revision "B" or later (product number ends with
the letter "B" or later, e.g., J4858B, J4859C) are required.
3-year, 4-hour onsite, 13x5 coverage for hardware (H4496E)
3-year, 4-hour onsite, 24x7 coverage for hardware (H2893E)
3-year, 4-hour onsite, 24x7 coverage for hardware, 24x7 software phone support (U6319E)
3-year, 24x7 SW phone support, software updates (UE264E)
Installation with minimum configuration, system-based pricing (U4826E)
Installation with HP-provided configuration, system-based pricing (U4830E)
4-year, 4-hour onsite, 13x5 coverage for hardware (UR884E)
4-year, 4-hour onsite, 24x7 coverage for hardware (UR885E)
4-year, 4-hour onsite, 24x7 coverage for hardware, 24x7 software phone (UR886E)
DA - 13280 Worldwide — Version 20 — December 12, 2013
The switch automatically adjusts to any voltage between 100-127 and 200-
240 volts and either 50 or 60 Hz
356 BTU/hr (376 kJ/hr)
100-127/200-240 VAC
2.1/1.1 A
64 W
105 W
50/60 Hz
Idle power is the actual power consumption of the device with no ports
connected.
Maximum power rating and maximum heat dissipation are the worst-case
theoretical maximum numbers provided for planning the infrastructure with
fully loaded PoE (if equipped), 100% traffic, all ports plugged in, and all
modules populated.
EN 55024, CISPR 24
IEC 61000-4-2; 4 kV CD, 8 kV AD
IEC 61000-4-3; 3 V/m
IEC 61000-4-4; 1.0 kV (power line), 0.5 kV (signal line)
IEC 61000-4-5; 1 kV / 2 kV AC, 1 kV signal, 0.5 kV DC
IEC 61000-4-6; 3 V
IEC 61000-4-8; 1 A/m
IEC 61000-4-11; > 95% reductions, 0.5 period; 30% reduction, 25 periods
IEC 61000-3-2
IEC 61000-3-3