Configuring The Macaddresselseuserloginsecure Mode - 3Com 4500G Family Configuration Manual

24/48 port
Hide thumbs Also See for 4500G Family:
Table of Contents

Advertisement

MAC ADDR
1234-0300-0011
---
1 mac address(es) found

Configuring the macAddressElseUserLoginSecure Mode

Network requirements
The client is connected to the switch through GigabitEthernet 1/0/1. The switch authenticates the client
by the RADIUS server. If the authentication succeeds, the client is authorized to access the Internet.
Restrict port GigabitEthernet 1/0/1 of the switch as follows:
Allow more than one MAC authenticated user to log on.
For 802.1X users, perform MAC authentication first and then, if MAC authentication fails, 802.1X
authentication. Allow only one 802.1X user to log on.
Set fixed username and password for MAC-based authentication. Set the total number of MAC
authenticated users and 802.1X-authenticated users to 64.
Enable NTK to prevent frames from being sent to unknown MAC addresses.
See
Figure
1-2.
Configuration procedure
Configurations on the host and RADIUS servers are omitted.
1)
Configure the RADIUS protocol
The required RADIUS authentication/accounting configurations are the same as those in
the userLoginWithOUI
2)
Configure port security
# Enable port security.
<Switch> system-view
[Switch] port-security enable
# Configure a MAC authentication user, setting the user name and password to aaa and 123456
respectively.
[Switch] mac-authentication user-name-format fixed account aaa password simple 123456
# Specify ISP domain sun for MAC authentication.
[Switch] mac-authentication domain sun
# Set the 802.1X authentication method to CHAP. (This configuration is optional. By default, the
authentication method is CHAP for 802.1X.)
[Switch] dot1x authentication-method chap
# Set the maximum number of secure MAC addresses allowed on the port to 64.
[Switch] interface gigabitethernet 1/0/1
[Switch-GigabitEthernet1/0/1] port-security max-mac-count 64
# Set the port security mode to macAddressElseUserLoginSecure.
[Switch-GigabitEthernet1/0/1] port-security port-mode mac-else-userlogin-secure
# Set the NTK mode of the port to ntkonly.
[Switch-GigabitEthernet1/0/1] port-security ntk-mode ntkonly
VLAN ID
STATE
1
Learned
---
Mode.
PORT INDEX
GigabitEthernet1/0/1
1-17
AGING TIME(s)
AGING
Configuring

Hide quick links:

Advertisement

Chapters

Table of Contents
loading

Table of Contents