[PROJECTOR SETUP] menu

[REMOTE2 MODE]

You can set the <REMOTE 2 IN> terminal.
1) Press ▲▼ to select [REMOTE2 MODE].
2) Press ◀▶ to switch [REMOTE2
MODE].
z The setting will change as follows each time
you press the button.
[DEFAULT]
The pin assignment of the
<REMOTE 2 IN> terminal is used
[DEFAULT]
by the factory default setting of the
projector.
(
Used to change the setting of the
[USER]
<REMOTE 2 IN> terminal.
■ When selecting [USER] in Step 2)
3) Press the <ENTER> button.
4) Press ▲▼ to select an item from
[PIN2] to [PIN8], and press ◀▶ to
switch the setting.

[STATUS]

Displays the status of the projector.
1) Press ▲▼ to select [STATUS].
2) Press the <ENTER> button.
3) Press ◀▶ to switch the pages.
Displays the input terminal currently
[INPUT]
selected.
[NAME]
Displays the input signal name.
[SIGNAL
Displays the frequency of the input
FREQUENCY]
signal.
[PROJECTOR
Displays the operation hours of the
RUNTIME]
projector.
[LAMP1]
*1
Displays the lighting time of the lamp 1.
[LAMP2]
Displays the lighting time of the lamp 2.
*1
[INTAKE AIR
Displays the status of the air intake
TEMP.]
temperature of the projector.
[OPTICS
Displays the status of the internal
MODULE TEMP.]
temperature of the projector.
Displays the status of the
[AROUND
temperature around the lamps of
LAMP TEMP.]
the projector.
[PROJECTOR
Displays the type of the projector.
TYPE]
[SERIAL
Displays the serial number of the
NUMBER]
projector.
[LAMP UNIT
Displays the model no. of the lamp
MODEL NO.]
unit.
64 - ENGLISH
[USER]
page 100)
[LAMP1 SERIAL
Displays the serial number of the
NUMBER]
lamp 1.
[LAMP2 SERIAL
Displays the serial number of the
NUMBER]
lamp 2.
[MAIN
Displays the main version of the
VERSION]
firmware of the projector.
Displays the sub version of the
[SUB VERSION]
firmware of the projector.
[NETWORK
Displays the network version of the
VERSION]
projector.
z [POWER ON TIMES]:
Displays the number of times the
power is turned on.
z [LAMP1 ON]:
Displays the number of times the
lamp 1 is turned on.
[ON COUNT]
z [LAMP2 ON]:
Displays the number of times the
lamp 2 is turned on.
z [SHUTTER]:
Displays the number of times the
shutter function is used.
[LAMP1]
Displays the details of the usage time.
[LAMP2]
Displays the details of the usage time.
[NUMBER OF
Displays the number of registered
ENTRY SIGNAL]
signals.
[REMOTE2
Displays the control status of the
STATUS]
REMOTE2.
*1: The lamp lighting time displayed is actual time.
The following conversion is required to calculate the
guideline for lamp replacement.
Time to replace the lamp =
The usage time when [LAMP POWER] is
set to [HIGH] +
(the usage time when [LAMP POWER] is
set to [LOW] x 2 ÷ 3)
Note
z The contents of the status can be sent via E-mail
when the <ENTER> button is pressed while the
status is displayed.