Write Multiple Ext (39H); Figure 128 Write Multiple Ext Command (39H) - Hitachi HTS541616J9AT00 - Travelstar 160 GB Hard Drive Specifications

2.5 inch ata/ide hard disk drive
Hide thumbs Also See for HTS541616J9AT00 - Travelstar 160 GB Hard Drive:
Table of Contents

Advertisement

14.49 Write Multiple EXT (39h)

Command Block Output Registers
Register
Data Low
Data High
Feature
Current
Previous
Sector Count
Current
Previous
LBA Low
Current
Previous
LBA Mid
Current
Previous
LBA High
Current
Previous
Device
Command
Error Register
7
6
5
4
CRC UNC
0
IDN
0
0
0
V

Figure 128 Write Multiple EXT Command (39h)

The Write Multiple Ext command transfers one or more sectors from the host to the device, then the data is written
to the disk media.
Command execution is identical to the Write Sector(s) Ext command except that an interrupt is generated for each
block (as defined by the Set Multiple command) instead of for each sector. The sectors are transferred through the
Data Register 16 bits at a time.
Output Parameters To The Device
Sector Count Current
Sector Count Previous
LBA Low Current
LBA Low Previous
LBA Mid Current
LBA Mid Previous
LBA High Current
LBA High Previous
Input Parameters From The Device
LBA Low (HOB=0)
LBA Low (HOB=1)
LBA Mid (HOB=0)
LBA Mid (HOB=1)
LBA High (HOB=0)
LBA High (HOB=1)
Travelstar 5K160 (PATA) Hard Disk Drive Specification
7 6 5 4 3 2 1 0
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
V V V V V V V V
V V V V V V V V
V V V V V V V V
V V V V V V V V
V V V V V V V V
V V V V V V V V
V V V V V V V V
V V V V V V V V
-
1
- D -
-
-
0 0 1 1 1 0 0 1
3
2
1
0
0
ABT T0N AMN
0
V
0
0
The number of continuous sectors to be transferred low order, bits (7:0)
The number of continuous sectors to be transferred high order, bits (15:8). If zero is
specified in the Sector Count register, then 65,536 sectors shall be transferred.
LBA (7:0).
LBA (31:24).
LBA (15:8).
LBA (39:32).
LBA (23:16).
LBA (47:40).
LBA (7:0) of the address of the first unrecoverable error.
LBA (31:24) of the address of the first unrecoverable error.
LBA (15:8) of the address of the first unrecoverable error.
LBA (39:32) of the address of the first unrecoverable error.
LBA (23:16) of the address of the first unrecoverable error.
LBA (47:40) of the address of the first unrecoverable error.
174 / 188
Command Block Input Registers
Register
-
Data Low
-
Data High
-
Error
-
Sector Count
HOB=0 -
HOB=1 -
LBA Low
HOB=0 V V V V V V V V
HOB=1 V V V V V V V V
LBA Mid
HOB=0 V V V V V V V V
HOB=1 V V V V V V V V
LBA High
HOB=0 V V V V V V V V
HOB=1 V V V V V V V V
-
Device
Status
Status Register
7
6
5
4
BSY RDY DF DSC DRQ COR IDX
0
V
0
V
7 6 5 4 3 2 1 0
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
...See Below...
-
-
-
-
-
-
-
-
-
-
-
-
-
-
V -
-
-
-
-
-
-
...See Below...
3
2
1
0
ERR
-
0
-
V

Hide quick links: