Electrical Requirements - Electrolux EGC3322 User Manual

Hide thumbs Also See for EGC3322:
Table of Contents

Advertisement

A
A)
The by-pass screw
• If you change from natural gas G20 20
mbar to liquid gas, fully tighten the ad-
justment screw in.
• If you change from liquid gas to natural
gas G20 20 mbar, undo the by-pass
screw approximately 1/4 of a turn.
WARNING!
Make sure the flame does not go
out when you quickly turn the
knob from the maximum position
to the minimum position.
8.5 Electrical connection
• Do not pull the mains cable to discon-
nect the appliance. Always pull the
mains plug (if applicable).
• The appliance must not be connected
with an extension cable, an adapter or
a multiple socket. There is a risk of fire.
• Do not let the power cable to heat up
to a temperature of more than 90° C.
The cable should be guided by means
of clamps fixed to the side of the cabi-
net, in order to avoid any contact with
the equipment beneath the cooktop.
• Make sure that there is access to the
mains plug after the installation.

Electrical Requirements

Permanent electrical installation must
agree with the latest I.E.E. Regulations
and local Electricity Board regulations. For
your own safety the installation must be
done by a qualified electrician (e.g. your
local Electricity Board, or a contractor
who is on the roll of the National Inspec-
tion Council for Electrical Installation Con-
tracting [NICEIC]).
The manufacturer refuses to be
held responsible, if these safety
measures are not abided by.
Supply connections:
This hob has to be connected to 230 —
240 V ( 50 Hz) electricity supply.
Before carrying out the connection, make
sure:
1.
The limiter valve and the electrical
system can take the appliance load
(see the rating plate)
2.
The supply system is equipped with
an efficient earth connection in com-
pliance with the current standards
and regulations
3.
The outlet or omnipolar switch used
for connection is easily accessible
with the appliance installed.
The appliance is supplied with a 3 core
flexible power cable requiring a 13 amp
plug fitted with a 13 amp or 3 amp fuse
dependent on the load. You must pur-
chase and install the plug.
The wires in the cord are coloured as fol-
lows:
Green and yellow
Blue
Brown
Replacement of the connection cable
1.
Connect the green and yellow (earth)
wire to the terminal which is marked
with the letter 'E', or the earth symbol
, or coloured green and yellow.
2.
Connect the blue (neutral) wire to the
terminal which is marked with the let-
ter 'N' or coloured blue.
3.
Connect the brown (live) wire to the
terminal which is marked with the let-
ter 'L' and is always connected to the
network phase.
There must be no cut or stray strands of
wire present. The cord clamp must be
correctly attached to the outer sheath.
ENGLISH
13
- Earth
- Neutral
- Live