Download Print this page

GE GFK-0726B User Manual

State logic processor for series 90-30 plc.
Hide thumbs

Advertisement

Î
GE Fanuc Automation
State Logic Products
r
State Logic
Processor
t
For Series 90
-30 PLC
User's Guide
GFK -0726B
March 1998

Advertisement

   Related Manuals for GE GFK-0726B

   Summary of Contents for GE GFK-0726B

  • Page 1

    Î GE Fanuc Automation State Logic Products State Logic Processor For Series 90 -30 PLC User’s Guide GFK -0726B March 1998...

  • Page 2

    Features may be described herein which are not present in all hardware and software systems. GE Fanuc Automation assumes no obligation of notice to holders of this document with respect to changes subsequently made.

  • Page 3

    Fanuc. Within twenty (20) days after any such termination of this Agreement, Customer shall certify in writing to GE Fanuc that all use of the Licensed Software has ceased, and that same has been re- turned or destroyed, in accordance with GE Fanuc’s instructions.

  • Page 5

    Chapter 5. Specifications We Welcome Your Comments and Suggestions At GE Fanuc automation, we strive to produce quality technical documentation. After you have used this manual, please take a few moments to complete and return the Reader ’s Comment Card located on the next page.

  • Page 6: Table Of Contents

    Specifications Content of this Manual We Welcome Your Comments and Suggestions GFK-0726B State Logic Processor for Series 90–30 PLC User’s Guide – March 1998 Contents ......

  • Page 7

    Figure 4 2. W orkmaster II or PS/2 to SLP Cable Figure 4 3. Serial Port Assignments for Series 90 30 SLP Figure 4 4. WYE Cable Connections for Series 90 30 SLP GFK-0726B State Logic Processor for Series 90–30 PLC User’s Guide – March 1998 Contents .

  • Page 8

    ..........T able 5 3. FirmwareSpecifications GFK-0726B State Logic Processor for Series 90–30 PLC User’s Guide – March 1998 Contents .

  • Page 9: Chapter 1 State Logic Processor Description

    IBM-PC compatible computer. OnTOP , the On-Line Troubleshooting Operator Pro- gram, also runs on an IBM-PC compatible computer. For questions about programming or on-line functions, see the ECLiPS or OnTOP User’s Manuals. IBM-PC is a registered trademark of International Business Machines Corporation. GFK-0726B -30 PLC chas-...

  • Page 10: Physical Description

    Î Î Î Î Î Î Î Î Î Î Î Î Î Î Î Î Î Î Î Î Î Î Î Î Î Î Î Î Î Î Î Î Î Î Î Î Î Î Î GFK-0726B...

  • Page 11

    The SLP comes with a battery to maintain memory when power is removed. This is a lithium battery which is installed as shown in the SLP drawings. When the battery reaches a low charge, this condition is reported to the PLC fault table. Chapter 1 State Logic Processor Description GFK-0726B CURRENTLY Î INSTALLED BATTERY Î...

  • Page 12: Operational Description

    Therefore, if some outputs of a byte are not named in the SLP program, ECLiPS issuses a warning that the other outputs in that byte are changed when the program executes. State Logic Processor for Series 90–30 PLC User’s Guide – March 1998 GFK-0726B...

  • Page 13: Chapter 2 Installation And Maintenance

    Press down firmly to lock the module in place, but do not use excessive force. Power up the PLC rack. The Status LED flashes during power-up diagnostics. The LED comes on steady when the SLP is ready for operations. GFK-0726B section level 1 1 figure bi level 1...

  • Page 14: Configuration

    During program execution the CPU must be in run mode with the outputs enabled. Use LM90-30 to set the status of the CPU before executing the State Logic program. Logicmaster is a trademark of GE Fanuc Automation North America, Inc. State Logic Processor for Series 90-30 PLC User’s Guide – March 1998...

  • Page 15: Battery

    To replace the battery, connect the new battery to the extra set of battery connections then disconnect the old battery. A Product Safety Data Sheet for the battery is available. Order from GE Fanuc using number GFK-0633. Chapter 2 Installation and Maintenance...

  • Page 16: Chapter 3 Troubleshooting

    Chapter Troubleshooting This chapter provides procedures for diagnosing State Logic Processor (SLP) problems. If these procedures do not solve the problem, contact the GE Fanuc Hotline (1-800-828-5747) for assistance. Status LED is not ON Steady Check that power is supplied to the I/O rack housing the SLP . Try removing and reinstalling the SLP .

  • Page 17

    4. When connecting some device to the programming port, make sure that you exit ECLiPS or OnTOP normally before disconnecting from the SLP . 5. If there are still problems contact the GE Fanuc Hotline for assistance. State Logic Processor for Series 90-30 PLC User’s Guide – March 1998...

  • Page 18: Chapter 4 Serial Communications

    ECLiPS or OnTOP normally before disconnect- ing from the SLP . Either of these ports may also be a CCM port. The CCM port uses the GE Fanuc CCM2 protocol for all communications. This protocol is used for connecting the SLP with a host computer which collects data and changes data in the SLP .

  • Page 19: Programming Serial Communications

    Since no port is specified in this example, information is sent to the programming port. For a more detailed discussion of programming serial input and output, refer to the Ref- erence Section of the ECLiPS User’s Manual. State Logic Processor for Series 90-30 PLC User’s Guide – March 1998 GFK-0726B...

  • Page 20: Serial Port Setup

    TOP to the SLP . The only options which can be changed on the ECLiPS or OnTOP serial port configuration are selecting COM1 or COM2 and changing the baud rate. Chapter 4 Serial Communications GFK-0726B Change Programming Port Enable/Disable CCM Port...

  • Page 21

    Stop Transmit Enabled on Receive Disabled Receiver Enabled Always On Disabled Line Feed After Enabled Carriage Return Disabled Auto Echo Enabled Disabled XON/X OFF Enabled Protocol Disabled End of Message Hex OD (Carriage Character Return * Default Settings are Underlined GFK-0726B...

  • Page 22: Serial Cable

    Serial Cable The State Logic Processor (SLP) is designed to work with two GE Fanuc standard serial cables. One cable is the Mini Converter Kit that comes with the ECLiPS. The other is the PCM to IBM-PC cable. Use the RS-422/485 serial cables to connect to Port 2, if RS-422/485 communications are used.

  • Page 23

    25– PIN MALE a42832 30 chassis. a42832 SHLD 25-PIN CONNECTOR a45089 Î Î Î Î Î Î Î Î Î Î Î Î Î Î Î Î SHLD Î Î 25– PIN 25– PIN 25– PIN FEMALE FEMALE MALE GFK-0726B...

  • Page 24

    Hardware flow control lines must be used when communicat- ing with the SLP using RS-232. The flow control lines are not used for RS-422/485 com- munications. Figure 4-3. Chapter 4 Serial Communications GFK-0726B Î Î Î Î Î Î Î SHIELD Î Î Î...

  • Page 25

    Î Î Î Î Î RS–485 RD ( B’ ) Î Î Î Î Î Î Î Î Î Î Î Î a44225 RS–232 25–PIN FEMALE- CONNECTOR PIN 1 PORT 1 PORT 2 RS–232/RS–485 PIN 1 25–PIN FEMALE CONNECTOR GFK-0726B...

  • Page 26: Chapter 5 Specifications

    Battery Shelf LIfe Battery Memory Retention with Power OFF Operating Temperature Storage Temperature Humidity (non-condensing) Vibration Shock Table 5-2. Standards GFK-0726B section level 1 1 figure bi level 1 table_big level 1 HardwareSpecifications 485, 380 C 0912, JIS C 0911...

  • Page 27

    90-30 SLP I/O and Register Specifications State Logic Processor for Series 90-30 PLC User’s Guide – March 1998 +/– 3.402823E+38) 32 BIT IEEE Type Capacity 1024 1280 2048 1000 1000 80 Characters Unlimited 1/100 second 3000 46 K Bytes 1000 3000 GFK-0726B...