Download Print this page

GE DCVH680EJ Dimensions And Installation Information page 3

7.0 cu. ft. super capacity frontload electric dryer

Advertisement

DCVH680EJ
GE
7.0 Cu. Ft. Super Capacity Frontload Electric Dryer
®
Dryer Exhausting Information – Metal Duct Only
For complete information, see installation instructions packed with your dryer.
Ducting Materials: For best performance, this dryer should be vented with 4" diameter all
rigid metal exhaust duct. If "all rigid metal" duct cannot be used, then "flexible all metal"
venting can be used, but it will reduce the maximum recommended duct length.
Exhaust Length Calculation:
1. Determine the number of 90° turns needed for your installation. If you exhaust to the
side or bottom of dryer, add one turn.
2. The maximum length of 4' rigid (aluminum or galvanized) duct which can be tolerated is
shown in the table. The maximum length for flexible ducts are less than for rigid duct.
A turn of 45° or less may be ignored. Two 45° turns within the duct length should be
treated as a 90° elbow.
A turn over 45° should be treated as a 90° elbow.
Exhausting the dryer to the outside is strongly recommended to prevent large amounts
of moisture and lint from being blown into the room. Gas dryers or any dryer located in a
closet must be exhausted to the outside.
Caution: For personal safety do not terminate exhaust into a chimney, under any enclosed
house floor (crawl space), or into an attic, since the accumulated lint could create a fire
hazard or moisture could cause damage. Never terminate the exhaust into a common duct
or plenum with a kitchen exhaust, since the combination of lint and grease could create a
fire hazard.
Exhaust ducts should be terminated in a dampered wall cap to prevent back drafts, bird
nesting, etc. The wall cap must also be located at least 12" above the ground or any other
obstruction with the opening pointed Down.
Other terminations, such as louvered wall boxes, are acceptable provided they are
equivalent to a 4" opening dampered wall cap.
For more information on venting kits and accessories, please call 1-800-GE-CARES.
GE Dryer Vent
Best Performance
Maximum Length
Rigid Metal Duct
Exhaust Hood Type
A
4
Number
B
of
90°
2-1/2
Turns
4" Opening
0
90 ft.
1
60 ft.
Front Loading
2
45 ft.
Dryers
3
35 ft.
4
25 ft.
Specification Revised 1/08
Maximum Length
of 4" Dia.
of 4" Dia.
Flexible Metal Duct
Exhaust Hood Type
B
A
A
2-1/2"
2-1/2"
Opening
4" Opening
Opening
60 ft.
55 ft.
45 ft.
45 ft.
40 ft.
30 ft.
35 ft.
30 ft.
20 ft.
25 ft.
20 ft.
15 ft.
15 ft.
15 ft.
10 ft.
Listed by
Underwriters
Laboratories
B
360455

Advertisement

loading

This manual is also suitable for:

Dcvh680ejbbDcvh680ejmrDcvh680ejmsDcvh680ejww