1. Prepare for Setup

Note the following before the setup:
Notice
1.
Exit all applications and shutdown the OS.
2.
Press the POWER switch on the server to turn off the power of the server.
3.
Completely remove the server from the Blade Enclosure.
4.
Remove the side cover and several components on the server.
Refer to the User's Guide of the server to install or remove components including the
side cover.
Check
Only a single disk array controller can be installed in a server.
Some limitations may be imposed on the installation to the mezzanine slot depending
on the type of the server. Before installation, check the limitations by referring to the
User‟s Guide of the server. Only a single Type 2 Mezzanine card can be installed in a
server.
HDD‟s to be connected to the disk array controller should have the same
specifications. Contact your service representative for HDD‟s which can be
connected to the disk array controller.
Coexistence with other mezzanine cards (e.g., LAN controller, SCSI controller, etc.)
may be limited. Before using the disk array controller with other mezzanine cards,
ask your service representative whether the disk array controller can coexist with
them.