INSTALL WINDOW GASKET AND
8
LOCKING BRACKET
A
Cut the foam top window gasket to the
window width.
B
Stuff the foam between the glass and the
window to prevent air and insects from
getting into the room.
9
REPLACE AIR CONDITIONER IN
CASE
Carefully slide the air conditioner back into
A
the case.
Attach the power cord to the base pan with
B
the clamp.
Installation Instructions
Base pan
Power cord
Clamp
21
Attach the window locking bracket with 1 type E
C
screw.
When the wall outlet is to the left, extend the
C
cord under the unit and hold it in place with the
clamp.
Reinstall the locking plate with the tab behind
D
the wall case flange. Tighten the screw.
Locking
plate
Tighten
screw
E
Reattach the front grille. An opening for the
power cord is on the bottom of the front grille.
Fill holes and cracks with caulking provided by
F
the installer
.
Power cord