Oregon Scientific RMR383HGA_M_OP User Manual
Oregon Scientific RMR383HGA_M_OP User Manual

Oregon Scientific RMR383HGA_M_OP User Manual

Wireless indoor / outdoor thermometer with indoor humidity and self-setting atomic clock

Advertisement

Quick Links

Wireless Indoor / Outdoor Thermometer
with Indoor Humidity and
Self-Setting Atomic Clock
Model: RMR383HGA
USER MANUAL

INTRODUCTION

Thank you for selecting this Oregon Scientific
Indoor / Outdoor Thermometer with Indoor Humidity and Self-
Setting Atomic clock (RMR383HGA). This clock is supplied
with a remote sensor (THN132N) and can support up to 3
sensors in total (additional sensors sold separately).
NOTE Please keep this manual handy as you use your new
product. It contains practical step-by-step instructions, as well
as technical specifications and warnings you should know
about.
CLOCK OVERVIEW

FRONT VIEW

1. SNOOZE
3. Clock / Alarm Area
4. ALARM: View alarm status; set alarm

BACK VIEW

1.
/
: Increase / decrease setting; activate /
deactivate clock reception signal
2. MODE: Change settings / display
3. CHANNEL: Switch remote sensor display
4. MEM: View current, maximum and minimum
temperature / humidity
5. °C / °F: Select temperature unit
7. TEMP / HUMIDITY HI / LO
: Change settings
or enable / disable hi or lo temperature / humidity
alarm
8. RESET: Reset unit to default settings
9. ZONE: Toggle US time zone
10. Battery compartment

LCD DISPLAY

Temperature and Humidity area:
RMR383HGA_M_R6
1. Heat Index icon
2. Hi / lo temperature alarm
3. Max / min temperature icon
4. Sensor reception icon
6. Battery low icon
7. Hi / lo humidity alarm
8. Max / min humidity icon
9. Ice warning is active
10. Temperature trend
11. Temperature
12. Heat Index warning
13. Humidity
14. Humidity trend
Clock / Alarm area:
TM
Wireless
1. Clock signal reception
2. AM / PM mode selected
3. Alarm mode
4. Alarm set
5. AM / PM mode selected
6. Alarm time
7. US time zone

8. Clock

REMOTE SENSOR (THN132N)
1. LED indicator

GETTING STARTED

BATTERIES

Insert batteries before first use, matching the polarity (+ and
-). Press RESET after each battery change.
��
indicates main unit batteries are low.
NOTE Do not use rechargeable batteries. We recommend
that you use alkaline batteries with this product for longer
usage and lithium batteries in temperatures below freezing.

REMOTE SENSOR

The sensor collects temperature readings approx. every 40
seconds and sends them to the main unit. The main unit can
collect data from up to 3 sensors.
To set up the sensor:
1. Slide open the battery door.
2. Insert the batteries, matching the polarity (+ / -). Reset
the sensor after each battery change.
3. Select a channel. Make sure you use a different channel
for each sensor.
��
��
��
��
��
1
4. Close the battery compartment.
5. Secure the sensor in the desired location using the wall
mount or table stand.
For best results:
Place the sensor out of direct sunlight and moisture.
Do not place the sensor more than 30 m (100 ft) from the
main (indoor) unit.
Position the sensor so that it faces the main (indoor)
unit, minimizing obstructions such as doors, walls, and
furniture.
Place the sensor in a location with a clear view to the
sky, away from metallic or electronic objects.
Position the sensor close to the main unit during cold
winter months as below-freezing temperatures may affect
battery performance and signal transmission.
The transmission range may vary depending on many factors.
You may need to experiment with various locations to get
the best results.
Standard Alkaline batteries contain significant amounts of
water. Because of this they will freeze in low temperatures
of approximately -12°C (10°F). Disposable Lithium batteries
have a much lower threshold for temperature with an
estimated freezing range of below -30°C (-22°F).
Wireless ranges can be impacted by a variety of factors
such as extremely cold temperatures. Extreme cold may
temporarily reduce the effective range between the sensor
and the base station. If the unit's performance fails due to
low temperature, the unit will resume proper functioning as
the temperature rises to within the normal temperature range
(i.e. no permanent damage will occur to the unit due to low
temperatures).

SENSOR DATA TRANSMISSION

The sensor reception icon in the temperature and humidity
area shows the status.
and Humidity Area)
To search for a sensor:
Simultaneously, press and hold MEM and CHANNEL for
2 seconds.
1. Wall mount
2. Battery compartment
NOTE If the sensor is still not found, check the batteries,
3. Battery door
obstructions, and remote unit location.
4. Table stand
5. RESET
6. CHANNEL switch
CLOCK

CLOCK RECEPTION

This product is designed to synchronize its date and time
automatically once it is within range of the WWVB-60
signal from the atomic clock in Fort Collins, Colorado.
The clock collects the radio signals whenever it is within 3219
km (2000 miles) of a signal.
NOTE Press ZONE to select the US time zone: Pacific (P),
Eastern (E), Central (C) or Mountain (M).
NOTE Initial reception takes 2-10 minutes for first set up or
when RESET is pressed. Once complete, the reception icon
will stop blinking. If the signal is weak, it can take up to 24
hours to get a valid signal.

RECEPTION SIGNAL

Clock signal reception indicator:
STRONG SIGNAL
To enable and force a signal search:
Press and hold
To disable the signal reception:
Press and hold

SET CLOCK

If the clock signal reception is enabled and a signal is being
received the clock does not need to be manually set.
To manually set the clock:
1. Press and hold MODE for 2 seconds.
2. Press
3. Press MODE to confirm.
4. The setting sequence is: 12/24 hour format, hour, minute,
year, date / month format, month, date, and display
language.
2006.4.7, 10:19 AM
ICON
DESCRIPTION
Main unit is searching for the
sensor(s)
A channel has been found and
sensor signal is being received
and "- - . -"
The sensor cannot be found.
(Temperature
Search for the sensor or
check batteries
WEAK SIGNAL
NO SIGNAL
for 2 seconds.
for 2 seconds.
and
to change the settings.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the RMR383HGA_M_OP and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Oregon Scientific RMR383HGA_M_OP

  • Page 1 Do not place the sensor more than 30 m (100 ft) from the main (indoor) unit. INTRODUCTION • Position the sensor so that it faces the main (indoor) Thank you for selecting this Oregon Scientific Wireless unit, minimizing obstructions such as doors, walls, and � �...
  • Page 2 The comfort zone assesses the climate based on current Visit our website (www.oregonscientific.com) to learn more temperature and humidity measurements. TEMPERATURE AND HUMIDITY about Oregon Scientific products such as digital cameras; MP3 players; children’s electronic learning products and ICON TEMPERATURE...