Kenmore 30" FREESTANDING ELECTRIC RANGE WITH DOUBLE OVENS Installation Instructions Manual page 9

30" (76cm) freestanding electric range with double ovens
Hide thumbs Also See for 30" FREESTANDING ELECTRIC RANGE WITH DOUBLE OVENS:
Table of Contents

Advertisement

Available languages

Available languages

Direct Wire Installation:
Copper or Aluminum
Wire
This range may be connected directly to the fuse disconnect
or
circuit breaker box. Depending on your electrical supply, make
the required 3-wire or 4-wire connection.
1. Strip outer covering back 3" (7.6 cm) to expose wires. Strip
the insulation back 1" (2.5 cm) from the end of each wire.
4=
Attach terminal lugs to line I (black), neutral (white), and line 2
(red) wires. Loosen (do not remove) the set screw on the front
of the terminal lug and insert exposed wire end through
bottom of terminal lugs. Securely tighten set screw to XX Ibs-
in. torque. See Bare Wire Torque Specifications
chart.
(7.6 cm)
2. Allow enough slack in the wire to easily attach the wiring
terminal block,
3. Complete electrical connection according to your type of
electrical supply (4-wire or 3-wire connection).
4-wire
Connection:
Direct Wire
Use this method for:
New branch-circuit
installations (1996 NEC)
Mobile homes
Recreational vehicles
In an area where local codes prohibit grounding through the
neutral
1. Part of metal ground strap must be cut out and removed.
A
A. Metal ground strap
B. Discard
C. Ground-link screw
2. Use Phillips screwdriver to remove the ground-link
screw
from the back of the range. Save the ground-link
screw and
the end of the ground-link
under the screw.
3. Pull the conduit through the strain relief on cord/conduit
plate
on bottom of range. Allow enough slack to easily attach
wiring to the terminal block.
G
F
E
A. Terminal block
E. Neutral (white) wire
B. Ground-link
screw
F. Line 1 (black) wire
C. Cord/conduit
plate
G. Bare (green) ground wire
D. Line 2 (red) wire
C
B
N
g
g
g
N
A. Terminallug
B. Set screw
C. Line ! (black) wire
D. Neutral (white) wire
E.Line 2 (red) wire
Bare Wire Torque Specifications
Attaching terminal lugs to the terminal block - 20 Ibs-in. (2.3 N-m)
Wire Awg
Torque
8 gauge copper
25 Ibs-in, (2,8 N-m)
6 gauge aluminum
35 Ibs-in, (4,0 N-m)
5. Use Phillips screwdriver to connect the bare (green) ground
wire to the range with the ground-link
screw. The ground wire
must be attached first and must not contact any other
terminal.
6. Use %" nut driver to connect the neutral (white) wire to the
center terminal block post with one of the 10-32 hex nuts.
C
A. 10-32 hex nut
B. Line 1 (black)
C. Bare (green) ground wire
D. Ground-link
screw
\
D
x
E
E. Neutral (white) wire
F. Line 2 (red)
G. Terminal lug
7. Connect line 1 (black) and line 2 (red) wires to the outer
terminal block posts with 10-32 hex nuts.
8. Securely tighten hex nuts.
9. Replace terminal block access cover.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 30" FREESTANDING ELECTRIC RANGE WITH DOUBLE OVENS and is the answer not in the manual?

Table of Contents