Power Supply Cord
Electrical
Shock Hazard
Disconnect
power before servicing.
Use a new 40 amp power supply cord.
Plug into a grounded
outlet.
Failure to follow these instructions can result in death,
fire, or electrical shock.
Direct Wire
Electrical Shock Hazard
Disconnect power before servicing.
Use 8 gauge copper or 6 gauge aluminum
wire.
Electrically ground range.
Failure to follow these instructions can result in death,
fire, or electrical shock.
1. Disconnect
power.
2. Use Phillips screwdriver to remove the terminal block cover
........
screw located on the back of the range. Pull cover down and
toward you to remove cover.
3. Remove plastic tag holding three 10-32 hex nuts from the
middle post of the terminal block.
4. Add strain relief.
Style 1: Power supply cord strain relief
•
Assemble a UL listed strain relief in the opening.
A, UL listed strain relief
•
Feed the power supply cord through the strain relief in the
cord/conduit
plate on bottom of range. Allow enough
slack to easily attach the wiring to the terminal block.
•
Tighten strain relief screw aqainst the power supply cord.
Style 2: Direct wire strain relief
•
Use Phillips screwdriver to remove screws and slide
cord/conduit
plate down and out.
Need help?