iNSTALLATiON INSTRUCTIONS
VENTING THE DRYER {cont.)
Ductwork
0
65 ft. (19.8 m)
45 ft. (13.7 m)
Recommended
1
55 ft. (16.8 m)
35 ft. (10.7 m)
(f--]]_'L_
2
47 ft. (13.7 m)
30 ft. (9.1 m)
3
36 ft. (11.0 m)
25 ft. (7.6 m)
(_02om/
(_02om/
4
28 ft. (8.5 m)
20 ft. (6.1 m)
Use Only for Short
0
55 ft. (16.8 m)
35 ft. (10.7 m)
Run Installations
1
47 ft. (13.7 m)
27 ft. (8.1 m)
---_
2
41 ft. (12.5 m)
21 ft. (6.4 m)
3
30 ft. (9.1 m)
17 ft. (5.2 m)
(63_o,,,/
4
22 ft. (6.7 m)
15 ft. (4.5 m)
NOTE: Deduct 6 ft. (1.8 m) for each additional elbow. It is not recommended
to use more than four 90 ° elbows.
ROuting
and Connecting
Ductwork
Follow the guidelines below to maximize drying
performance and reduce lint buildup and
condensation
in the ductwork.
NOTE: Ductwork and fittings are NOT included
and must be purchased separately.
• Use 4-in. (10 cm) diameter rigid or semirigid
metal ductwork.
The exhaust duct run should be as short as
possible.
Use as few elbow joints as possible.
The male end of each section of exhaust duct
must point away from the dryer.
Use duct tape on all duct joints.
Insulate ductwork that runs through unheated
areas in order to reduce condensation
and lint
buildup on duct surfaces.
iMPORTANT: Failure to exhaust the dryer
correctly will void the dryer's warranty.
Correct
Venting
0
incorrect Venting
14