With the aid of the following guide, minor problems can be fixed without a service
call.
The door is not
properly closed.
The fuse is defective
or the breaker has
tripped.
– The water valves
are closed.
– The filters in the
water inlet hose
are dirty.
– Water pressure is
too low.
– The drain hose is
kinked.
– The drain pump is
blocked.
Close the door firmly.
Make sure the circuit breaker
has not tripped.
– Turn the program selector to
"Stop" f (the fault code
goes out).
– Press the "On/Off" button to
turn the machine off.
– Open the water valve or
clean the filters (see
"Machine care").
– Turn the machine on again
and reselect the program.
– Turn the program selector to
"Stop" f (the fault code
goes out).
– Press the "On/Off" button to
turn the machine off.
– Remove any kinks in the
hose. Clean the drain pump
(see "Machine care").
– Turn the machine on, run the
drain program then restart
the original program (see
additional program "Drain"
and "Turning on").