The machine must not be used
without all the filters in place. The
filters protect the circulation pump
from damage caused by foreign
objects.
The filter combination in the base of
the wash cabinet should be
inspected regularly and cleaned if
necessary.
Watch out for sharp objects which
could cause injury.
^ Press the two tabs together. Remove
and clean the coarse filter.
^ Put the clean filter back in position
and press until it clicks in place.
32
^ Remove the coarse filter.
^ Remove the fine filter (if fitted) from be-
tween the flat and the micro-fine filters.
^ To unscrew the micro-fine filter, grasp
the two tabs and turn counter-
clockwise twice.
^ Remove both filters together.
^ Clean the filters.
^ Replace the filter combination in
reverse order. The flat filter must lie
flat in the base of the wash cabinet.