Switch Installation

This chapter describes how to start your switch and how to interpret the power-on self-test (POST) that
ensures proper operation. It also describes how to install the switch.
Read the topics and perform the procedures in this order:

Preparing for Installation

Warnings
These warnings are translated into several languages in the Regulatory Compliance and Safety
Information for the Catalyst 3560-C and the 2960-C Switches guide.
Warning
Before working on equipment that is connected to power lines, remove jewelry (including rings,
necklaces, and watches). Metal objects will heat up when connected to power and ground and can
cause serious burns or weld the metal object to the terminals. Statement 43
OL-23803-02
Preparing for Installation, page 2-1
Verifying Switch Operation, page 2-5
Mounting the Switch, page 2-5
Installing a Cover for the Reset Button (Optional), page 2-24
Installing the Power Cord Retainer (Optional), page 2-25
Installing the Cable Guard (Optional), page 2-28
Connecting Devices to the Ethernet Ports, page 2-33
Warnings, page 2-1
Installation Guidelines, page 2-3
Equipment That You Supply, page 2-4
Box Contents, page 2-4
Powering the Switch, page 2-4
C H A P T E R
Catalyst 3560-C and 2960-C Switch Hardware Installation Guide
2
2-1

Advertisement

Table of Contents
loading

Summary of Contents for Cisco Catalyst 3560-C

  • Page 1: Switch Installation

    • Warnings These warnings are translated into several languages in the Regulatory Compliance and Safety Information for the Catalyst 3560-C and the 2960-C Switches guide. Warning Before working on equipment that is connected to power lines, remove jewelry (including rings, necklaces, and watches).
  • Page 2 Statement 1024 Warning Ultimate disposal of this product should be handled according to all national laws and regulations. Statement 1040 Catalyst 3560-C and 2960-C Switch Hardware Installation Guide OL-23803-02...
  • Page 3: Installation Guidelines

    (4 cm) of empty rack space above each switch. • Catalyst 3560CG-8PC-S, 2960C-8PC-L, 2960C-12PC-L, 3560C-8PC-S, and 3560C-12PC-S switches: Allow at least 1.75 in. (4 cm) clearance from the ends of the external heat sink fins. Catalyst 3560-C and 2960-C Switch Hardware Installation Guide OL-23803-02...
  • Page 4: Equipment That You Supply

    Drill with a #27 drill bit (0.144-inch [3.7 mm]) Box Contents The switch getting started guide on Cisco.com describes the box contents. If any item is missing or damaged, contact your Cisco representative or reseller for support. Powering the Switch Before installing the switch in a rack, on a desk, a shelf, or a wall, you should power on the switch and verify that it passes POST.
  • Page 5: Verifying Switch Operation

    If a switch fails POST, the System LED turns amber. POST failures are usually fatal. Call Cisco technical support representative if your switch fails POST. After a successful POST, unplug the power cord from the switch. Mount the switch in a rack on a desk or shelf, under a desk or shelf, or on a wall, as described in the “Mounting the Switch”...
  • Page 6: On A Desk Or Shelf (Without Mounting Screws)

    2-1. This ensures that the power cord faces the rear of the desk or shelf after the switch is installed. Wait before you attach the screw template to the desk or shelf. Note Catalyst 3560-C and 2960-C Switch Hardware Installation Guide OL-23803-02...
  • Page 7 Place the switch onto the mounting screws, and slide it forward until it locks in place. See Figure 2-2. Step 7 Warning To prevent airflow restriction, allow clearance around the ventilation openings to be at least: 3 in. (7.6 cm) Statement 1076 Catalyst 3560-C and 2960-C Switch Hardware Installation Guide OL-23803-02...
  • Page 8: Under The Desk- Or Shelf-Mounting

    Peel the adhesive strip off the bottom of the screw template, and attach it to the underside of the desk or Step 3 shelf. Catalyst 3560-C and 2960-C Switch Hardware Installation Guide OL-23803-02...
  • Page 9 Place the switch upside down onto the mounting screws, and slide it forward until it locks in place. See Step 7 Figure 2-4. To prevent airflow restriction, allow clearance around the ventilation openings to be at least: Warning 3 in. (7.6 cm) Statement 1076 Catalyst 3560-C and 2960-C Switch Hardware Installation Guide OL-23803-02...
  • Page 10: Wall Mounting

    Do not wall-mount the switch with its front panel facing up. Following safety regulations, wall-mount Caution the switch with its front panel facing down or to the side to prevent airflow restriction and to provide easier access to the cables. Catalyst 3560-C and 2960-C Switch Hardware Installation Guide 2-10 OL-23803-02...
  • Page 11 Step 7 Figure 2-5 Location of the Mounting Holes on the Switch 1.77 in. (4.49 cm) 2.67 in. (6.78) 3.72 in. (9.44 cm) 2.46. in. (6.24) 3.62 in. (9.19 cm) Switch Catalyst 3560-C and 2960-C Switch Hardware Installation Guide 2-11 OL-23803-02...
  • Page 12 T R Y Figure 2-7 Installing the Switch on a Wall Place the switch onto the mounting screws, and slide it down until it locks in place. See Figure 2-7. Step 8 Catalyst 3560-C and 2960-C Switch Hardware Installation Guide 2-12 OL-23803-02...
  • Page 13: With A Mounting Tray

    Mounting the Switch With a Mounting Tray The mounting kit (part number CMP-MGNT-TRAY=) is optional. You can order it when you order your switch, or you can order it later from your Cisco representative. The mounting kit ships contents: •...
  • Page 14 STA T DP LX MO DE SP D Se rie s Po E CO NS OL PO WE R OVE R ET HE RN Switch Mounting tray Sliding direction Desk Catalyst 3560-C and 2960-C Switch Hardware Installation Guide 2-14 OL-23803-02...
  • Page 15: Mounting Tray With A Magnet

    This example shows you how to mount the switch on a metal wall. You can use a similar procedure to mount the switch under a metal desk or on a metal desk. Catalyst 3560-C and 2960-C Switch Hardware Installation Guide 2-15...
  • Page 16 Number-10 Phillips pan-head screws Place one side of the magnet against the bottom of the mounting tray, as shown in Figure 2-13. Mount Step 3 the magnet and switch on a metal wall. Catalyst 3560-C and 2960-C Switch Hardware Installation Guide 2-16 OL-23803-02...
  • Page 17 To prevent airflow restriction, allow clearance around the ventilation openings to be at least: 3 in. (7.6 cm) Statement 1076 After you mount the switch, see the “After Installing the Switch” section on page 2-31 for information about configuring the switch. Catalyst 3560-C and 2960-C Switch Hardware Installation Guide 2-17 OL-23803-02...
  • Page 18: Attaching Brackets To The Switch

    Attaching the 19-inch Brackets for Rack-Mounting SYS T STA T DP LX MO DE Se rie s CO NS OL PO WE R OVE R ETH ER NE T Phillips flat-head screw Catalyst 3560-C and 2960-C Switch Hardware Installation Guide 2-18 OL-23803-02...
  • Page 19: Mounting The Switch In A Rack

    OVE R ETH ER NE T Phillips machine screws After you mount the switch, see the “After Installing the Switch” section on page 2-31 for information about the switch configuration. Catalyst 3560-C and 2960-C Switch Hardware Installation Guide 2-19 OL-23803-02...
  • Page 20: On A Din Rail

    Mounting the Switch On a DIN Rail The DIN-mount kit (part number CMP-DIN-MNT=) is optional. You can order it when you order your switch, or you can order it later from your Cisco representative. The DIN-mount kit contains: • Two number-10 Phillips pan-head screws •...
  • Page 21: Mounting The Switch On A Din Rail

    Position the switch directly in front of the DIN rail, making sure that the top of the DIN rail mount clip Step 1 hooks over the top of the DIN rail. See Figure 2-19. Catalyst 3560-C and 2960-C Switch Hardware Installation Guide 2-21 OL-23803-02...
  • Page 22 Lift lightly on the bottom of the switch to ensure that it is firmly locked in place. After you install the switch, see the “After Installing the Switch” section on page 2-31 for information about the switch configuration. Catalyst 3560-C and 2960-C Switch Hardware Installation Guide 2-22 OL-23803-02...
  • Page 23: Removing The Switch From A Din Rail

    Pull down on the DIN rail mount release tabs. As the clips release, lift the bottom of the switch. Step 2 Figure 2-20. Figure 2-20 Switch Removal Switch Catalyst 3560-C and 2960-C Switch Hardware Installation Guide 2-23 OL-23803-02...
  • Page 24: Installing A Cover For The Reset Button (Optional)

    Figure 2-22 Reset Cover on the Catalyst 2960CG-8PC-S Switch R E S E T R E S E T E S E T E S E T Switch Reset button cover Catalyst 3560-C and 2960-C Switch Hardware Installation Guide 2-24 OL-23803-02...
  • Page 25: Installing The Power Cord Retainer (Optional)

    The power cord retainer part number (PWR-CLP=) is optional. You can order it when you order your switch, or you can order it later from your Cisco representative. Choose the sleeve size of the power cord retainer based on the thickness of the cord. The smaller sleeve Step 1 can be snapped off and used for thin cords.
  • Page 26 (Optional) Use the small sleeve for thin power cords. Use the small sleeve to provide greater stability for Step 5 thin cords. Detach the sleeve, and slide it over the power cord. See Figure 2-26. Catalyst 3560-C and 2960-C Switch Hardware Installation Guide 2-26 OL-23803-02...
  • Page 27 Sleeve for thin power cords AC power cord Step 6 Secure the AC power cord by pressing on the retainer. See Figure 2-27. Figure 2-27 Securing the Power Cord in the Retainer Catalyst 3560-C and 2960-C Switch Hardware Installation Guide 2-27 OL-23803-02...
  • Page 28: Installing The Cable Guard (Optional)

    Installing the Cable Guard (Optional) The cable guard prevents tampering with the cables after the cables are installed. The cable guard (CMP-CBLE-GRD=) is not included with the switch, but you can order it from your Cisco representative. You can use the cable guard when the switch is mounted on a desk, under a desk, or on a wall.
  • Page 29 Ca ta lys t 29 60 -C Se rie s CO NS OL Cable guard Pivot direction for cable guard pivots Attach the cables to the switch. See Figure 2-31. Catalyst 3560-C and 2960-C Switch Hardware Installation Guide 2-29 OL-23803-02...
  • Page 30 Guide the connected cables through the slots in the front of the cable guard. Slide the cable guide in as Step 4 shown in Figure 2-33. Tighten the screws. Figure 2-32 Guiding the Cables through the Guard Catalyst 3560-C and 2960-C Switch Hardware Installation Guide 2-30 OL-23803-02...
  • Page 31: After Installing The Switch

    • module more often than is absolutely necessary. To prevent ESD damage, follow your normal board and component handling procedures when • connecting cables to the switch and other devices. Catalyst 3560-C and 2960-C Switch Hardware Installation Guide 2-31 OL-23803-02...
  • Page 32: Removing Sfp Modules

    Step 5 Grasp the SFP module, and carefully remove it from the slot. Place the module in an antistatic bag or other protective environment. Step 6 Catalyst 3560-C and 2960-C Switch Hardware Installation Guide 2-32 OL-23803-02...
  • Page 33: Connecting Devices To The Ethernet Ports

    See the switch software configuration guide or the switch command reference on Cisco.com for more information about autonegotiation and auto-MDIX.
  • Page 34: Connecting To The Poe Ports

    The ports provide PoE support for 802.3af-compliant devices and also provide Cisco prestandard PoE support for Cisco IP Phones and Cisco Aironet Access Points. On a per-port basis, you can control whether or not a port automatically provides power to a connected IP phone or an access point.
  • Page 35: Where To Go Next

    Where to Go Next To change the switch settings, you can use the switch default configuration or use any of the management options described in the “Management Options”section. Catalyst 3560-C and 2960-C Switch Hardware Installation Guide 2-35 OL-23803-02...
  • Page 36 Chapter 2 Switch Installation Where to Go Next Catalyst 3560-C and 2960-C Switch Hardware Installation Guide 2-36 OL-23803-02...

This manual is also suitable for:

Catalyst 2960-c

Table of Contents