Cisco 6200 User Manual page 8

Advanced digital subscriber line access multiplexer (dslam)
Hide thumbs Also See for 6200:
Table of Contents

Advertisement

1
Hardware Description
Table 1-1
Specification
Components
Power input
Power consumption, fully loaded
Dimensions
Weight with no cards
Weight fully loaded
Operating temperatures
Storage temperature
Operating humidity
Storage humidity
1
2
3
Table 1-2
Category
NEBS
EMI
Safety
Immunity
1-8
Cisco 6200 User Guide
Cisco 6200 DSLAM Specifications
2
1
A fully loaded chassis has 1 fan tray, 2 PEMs, 1 MPC, 1 NTC, 10 SLCs, covers, and dangler cables.
A chassis with no cards has 1 fan tray, 2 power entry modules, covers, and dangler cables.
The chassis can operate safely at short term operating temperatures only if all of the fans are working properly. If a fan fails
in a chassis that is experiencing an ambient temperature above 104 F (40 C), thermal damage may occur.
Standards and Certifications
Description
Bellcore SR-3580 to Level 3 (GR-63, GR-1089)
FCC Part 68 and part 15 Class A
CSA Class A
EN55022 Class A
AS/NRZ 3548 Class A
VCCI Class 1
UL 1950
EN60950
CSA C22.2 No. 950
AUSTEL TS001
AS/NZS 3260
EN61000-4-2/IEC-1000-4-2
EN61000-4-3/IEC-1000-4-3
EN61000-4-4/IEC-1000-4-4
EN61000-4-5/IEC-1000-4-5
EN61000-4-6/IEC-1000-4-6
EN61000-4-11/IEC-1000-4-11
Description
14-slot card compartment
Backplane
Fan compartment
Power module compartment
Dual inputs, each –48 VDC
Tested voltages: –48V and –57V
Tolerance limits: –42V to –57V
Maximum input current: 23A
1
With SLC 8CAPs: 820W
With SLC 8DMTs: 892W
Height: 23.6 in. (60.0 cm)
Width: 17.5 in. (44.4 cm) (mounting brackets not included)
Depth: 11.8 in. (30.0 cm)
48 lb (21.7 kg)
82.5 lb (37.4 kg)
Short term: 23 to 131 F (–5 to 55 C)
Long term: 32 to 104 F (0 to 40 C)
–40 to 158 F (–40 to 70 C)
15% to 90% noncondensing
10% to 95% noncondensing
78-5296-02
3
10/02/98

Hide quick links:

Advertisement

Table of Contents
loading