Sony BVME170A Operation Manual page 73

Professional video monitor
Hide thumbs Also See for BVME170A:
Table of Contents

Advertisement

Menu
OSD Notification
OSD Notification Reset
Input Detection
Detection
Pixel Threshold
Signal Level
SDI YCbCr 10bit
SDI RGB 10bit
SDI YCbCr 12bit
SDI RGB 12bit
HDMI/DP YCbCr
Function and operation ([
Sets whether or not to display the message of an error notification on the screen when the
error is detected ([Off] or On).
Sets the method to reset the error detection mode.
[Auto]: Resets automatically after detecting the error.
Manual: Resets manually.
To reset the error detection, select Error Notify Clear (page 79) in the Function Switch
menu of the Function Setting menu or set Error Notify Clear to on by pressing the Error
1)
Notify Clear button
of the controller.
1) Error Notify Clear is assigned to a function button of the controller in the Function Key menu (page
92) of the Controller menu.
Sets the error detection of the input signal.
Sets whether or not to detect the error of the input signal (Off or [On]).
Sets the pixel number of the gamut error in the frame to notify the gamut error detection.
When the pixel number of the error is over the set pixel number, the detection is notified.
Set to 00000 to 65535. [00000]
Sets the upper and lower lines of every signal to detect the gamut error.
Upper Limit (upper limit)
Y: 0000 to 1023 [0983]
Cb: 0000 to 1023 [1004]
Cr: 0000 to 1023 [1004]
Lower Limit (lower limit)
Y: 0000 to 1023 [0020]
Cb: 0000 to 1023 [0019]
Cr: 0000 to 1023 [0019]
Upper Limit (upper limit)
G: 0000 to 1023 [0983]
B: 0000 to 1023 [0983]
R: 0000 to 1023 [0983]
Lower Limit (lower limit)
G: 0000 to 1023 [0020]
B: 0000 to 1023 [0020]
R: 0000 to 1023 [0020]
Upper Limit (upper limit)
Y: 0000 to 4095 [3935]
Cb: 0000 to 4095 [4019]
Cr: 0000 to 4095 [4019]
Lower Limit (lower limit)
Y: 0000 to 4095 [0080]
Cb: 0000 to 4095 [0077]
Cr: 0000 to 4095 [0077]
Upper Limit (upper limit)
G: 0000 to 4095 [3935]
B: 0000 to 4095 [3935]
R: 0000 to 4095 [3935]
Lower Limit (lower limit)
G: 0000 to 4095 [0080]
B: 0000 to 4095 [0080]
R: 0000 to 4095 [0080]
Upper Limit (upper limit)
Y: 0000 to 4095 [3935] (12bit conversion value)
Cb: 0000 to 4095 [4019] (12bit conversion value)
Cr: 0000 to 4095 [4019] (12bit conversion value)
Lower Limit (lower limit)
Y: 0000 to 4095 [0080] (12bit conversion value)
Cb: 0000 to 4095 [0077] (12bit conversion value)
Cr: 0000 to 4095 [0077] (12bit conversion value)
]: factory setting)
73
Function Setting Menu

Advertisement

Table of Contents
loading

This manual is also suitable for:

Bvme250aBvm-e170