Configuring a Vanguard Router
T0100-01, Revision B
This example highlights how to configure a Vanguard Router to carry LAN traffic
over a WAN using WANView. Point-to-Point LCON will be used.
Figure 3-2 below illustrates the functional diagram of the Vanguard Router and the
important parameters that should be configured. In this example, Node 200 and
Node 300 are configured to initiate calls to Node 100. When configuring Node 200
and Node 300's LAN Connection Tables, an entry must be made for the autocall
mnemonic. In addition, the mnemonic table must be configured.
Note
Default values are used for parameters not specified in the table.
Node 100
10.33.1.1
5
LCON 1
FRI-1S1
6
1
LCON 2
FRI-1S2
10.33.2.1
WAN Adaptor
Figure 3-2. WANView Functional Diagram - Point-to-Point LCON
Menu
Node 100
Node Name: Node 100
Node Address: 100
Port Number: 1
Port Type: FRI
Connection Type: SIMP
Clock Source:EXT
Highest Station Number: 2
Control Protocol Support:LMI
Port Number: 1
Station Number: 1
Station Type: Annex G
DLCI: 16
Station Number: 2
Station Type: Annex G
DLCI: 17
Port Number: 5
Port Type: ETH
FRI
WAN
Port 1
WAN Port
Node 200
Node Name: Node 200
Node Address: 200
Port Number: 1
Port Type: FRI
Connection Type: SIMP
Clock Source:EXT
Highest Station Number: 1
Control Protocol Support:LMI
Port Number: 1
Station Number: 1
Station Type: Annex G
DLCI: 16
Port Number: 5
Port Type: ETH
Configuration
Port 5
10.33.1.2
Node 200
Port 1
LAN
Port 1
Port 5
Node 300
10.33.2.2
LAN
Node 300
Node Name: Node 300
Node Address: 300
Port Number: 1
Port Type: FRI
Connection Type: SIMP
Clock Source:EXT
Highest Station Number: 1
Control Protocol Support:LMI
Port Number: 1
Station Number: 1
Station Type: Annex G
DLCI: 17
Port Number: 5
Port Type: ETH