Crossover Twisted-Pair Cable For 10 Mbps Or 100 Mbps Network Connection; Cable Diagram; Pin Assignments - HP ProCurve 2520G-PoE Series Installation And Getting Started Manual

Table of Contents

Advertisement

N o t e
Crossover Twisted-Pair Cable for
10 Mbps or 100 Mbps Network Connection
The Auto-MDIX operation of the 10/100 ports on the switch also allows you to
use crossover cables for all network connections, to PCs, servers or other end
nodes, or to hubs or other switches.
If any of these ports are given a fixed configuration, for example 100 Mbps/
Full Duplex, the ports operate as MDI-X ports, and crossover cables must be
then used for connections to hubs or switches or other MDI-X network
devices.

Cable Diagram

Pins 1 and 2 on connector "A" must be wired as a twisted pair to pins 3 and 6
on connector "B".
Pins 3 and 6 on connector "A" must be wired as a twisted pair to pins 1 and 2
on connector "B".
Pins 4, 5, 7, and 8 are not used in this application, although they may be wired
in the cable.

Pin Assignments

Switch End (MDI-X)
Signal
Pins
receive +
1
receive -
2
transmit +
3
transmit -
6
Twisted-Pair Cable/Connector Pin-Outs
Hub or Switch Port, or Other
MDI-X Port End
Pins
Signal
6
transmit -
3
transmit +
2
receive -
1
receive +
Specifications
A-11