Advertisement

Quick Links

Crime Guard 250i6
Crime Guar
Crime Guar
Crime Guar
Crime Guar
Owner's Guide
COVER PROVIDED IN
SEPARATE FILE
COPYRIGHT: OMEGA RESEARCH & DEVELOPMENT 2007
d 250i6
d 250i6
d 250i6
d 250i6

Advertisement

Table of Contents
loading

Summary of Contents for Crime Guard Crime Guard 250i6

  • Page 1 Crime Guar Crime Guard 250i6 Crime Guar d 250i6 d 250i6 d 250i6 Crime Guar Crime Guar d 250i6 Owner's Guide COVER PROVIDED IN SEPARATE FILE COPYRIGHT: OMEGA RESEARCH & DEVELOPMENT 2007...
  • Page 3: Replacement Transmitters

    Congratulations on the purchase of your Crime Guard 250i6 vehicle security Replacement or optional transmitters are readily available from the dealer from system. It is most important to note that the Crime Guard 250i6 has a unique and which you purchased your system; or may purchased directly from Omega flexible design, which allows the system to be installed in several configurations, Research and Development.
  • Page 4 Blue Light power wire, which is also located at the control unit and siren assembly. The Illuminates whenever any transmitter button is pressed. Crime Guard 250i6 may be operated by up to two transmitters. The “Arm” Button The “Disarm” Button...
  • Page 5: How To Program Transmitters To The System

    The Status Indicator Light and the LED Status Indicator Light are supplied with the ured and acknowledged by 1 or 2 chirps, select the next feature by re- Crime Guard 250i6 system kit, but are not absolutely necessary for the system’s peating Step 3 and Step 4.
  • Page 6: Arming The System

    • Another option is having the doors automatically lock when- be 1 chirp), or the “Disarm” Button to turn the feature off (the system’s ever the system is armed. This requires connecting an opt- response will be 2 chirps). ional interface (the Omega “DM-1”). Page 6 Page 19...
  • Page 7: System Armed & Activated

    In addition to detecting impacts to the vehicle and detecting a current draw from mode, and chirps made during the programming of features or transmitters. the battery (example- interior light illuminating from opened door), the 250i6 has a detection circuit which may be used to protect the hood, trunk or doors. If this 4.
  • Page 8: Disarming The System

    If a protected zone is still open at the end of the activation cycle, the system will continue to reactivate itself, for up to six The Crime Guard 250i6 vehicle security system has 6 programmable features activated cycles before it resets itself and ignores the violated zone.
  • Page 9: Silent Arming & Disarming

    Step 3: Within 5 seconds, Press the Valet/Override Switch. then reset itself. -The activated system will instantly disarm. • If the optional DM-1 doorlock interface was installed, the doors will also unlock upon disarming. When the Valet/Override Switch is pressed, and the system disarms, releasing the switch will place the system in standby mode.
  • Page 10: Remote Panic Operation

    To Activate Remote Panic: Press & Hold for 3 Seconds the “Arm” Indicator Light, the Crime Guard 250i6’s “ignition input” wire must also be Button OR the “Disarm” Button connected. If the Crime Guard 250i6 was not installed with the Valet/Override...
  • Page 11 Valet Mode prevents the system from becoming armed. Valet Mode is designed Remote Panic can be activated anytime, whether the vehicle’s ignition is turned for situations in which it is not convenient for the alarm portion of the system to be on or off, and has a 60 second duration (regardless of the 30 or 60 second acti- operational;...
  • Page 12: Valet Mode & Emergency Override

    Shock Sensor & Prewarning Press & Release the “Arm” Button THEN The Crime Guard 250i6 vehicle security system is equipped with a built-in “shock” sensor which detects impact to the vehicle. As vehicles differ structurally, and SECOND: THE SIREN WILL...
  • Page 13: Installation

    Installation Instructions for CONNECTION: To interrupt the vehicle's starter circuit, the starter wire must be your Crime Guard 250i6 security and convenience located and cut. It is recommended that this connection be done as close to the ignition switch as possible.
  • Page 14: Wiring Connections

    After the control unit and siren assembly has been mounted, follow the instructions Status Indicator Light: Mount the Status Indicator Light using the combination for each wire's connection. Please note that during the initial installation, as holder, or it may be mounted into an interior panel by drilling a 17/64” (6.5mm) hole. soon as the Black ground wire and Red Constant power wire have been The control module and siren assembly’s Pink wire must be routed to the Status connected, the system will enter Transmitter Programming Mode, which is...
  • Page 15: Wiring Diagram

    Although the Crime Guard 250i6 can have basic operations without them, the Wiring Diagram Valet/Override Switch and the Status Indicator Light greatly enhance the system. The Valet/Override Switch allows disarming the system without the transmitter See Installation Insert Page 10 for and placing the system into a state in which it cannot be armed.
  • Page 16 Wiring Connections the security system. Connecting this wire will prevent the system from being armed while the ignition switch is on, and its connection is required if the Valet/ Override is installed for the purpose of allowing the system to be disarmed without Black Wire - (- Ground Input): This wire’s connection is required for operation.
  • Page 17 in the engine compartment, the easiest way to locate the parking light wire is to Red Wire - (+12 Volts Input): This is the second of two wires in which connection is required for the system to operate. The Red wire's function is to supply Constant access a corner running light on the fender, or a front parking light in the front bumper or fascia.
  • Page 18 White Wires - (+12 Volts Flashing Light Outputs): While not necessary for the Control Trunk - Switching Trunk Hood Crime Guard 250i6’s basic operation, these wires greatly enhance the system’s Light Trigger Module / Siren operation, are usually very easy to connect. These are +12 Volts outputs for Connections...

Table of Contents