SPECIFICATIONS OF THE RADAR REMOTE DISPLAY
1. GENERAL
(1) Picture Tube
(2) Brightness
(3) Scanning method
(4) Range, Range Ring Interval, Number of Rings
Range (NM)
Ring Interval (NM) 0.0625 0.125 0.125 0.25 0.25 0.5 0.5 1 1 2 2 3 4 6
Number of Rings
(4) Input data
2. POWER SUPPLY
(1) Main Unit
3. ENVIRONMENTAL CONDITION
(1) Ambient Temperature
(2) Relative Humidity
(3) Water proofing
(4) Vibration
4. COATING COLOR
(1) Main Unit
FMD-1712
7 inch rectangular monochrome LCD
240(H) x 320(V) dots, Effective radar display area: 240 x 240 dots
80 cd min
Luster scan
0.125 0.25
0.5 0.75
2
2
4
3
Heading data, Bearing data, Trigger signal and Video signal
12-24 VDC: 0.6-0.3 A
-15°C to +55°C
95% at 40°C
IPX-5
IEC60945
Panel: N3.0, Chassis: 2.5GY5/1.5
1 1.5 2 3 4 6 8 12 16 24
4
3 4 3 4 3 4 4 4 4
SP - 1

Hide quick links: