TROUBLESHOOTING
First try the solutions suggested here and possibly avoid the cost of a service call...
Dryer will not run
Has a household fuse blown, or has a circuit breaker
tripped?
Replace the fuse or reset the circuit breaker. There may be
2 household fuses or circuit breakers for the electric dryer.
Check that both fuses are intact and tight, or that both circuit
breakers have not tripped. If the problem continues, call an
electrician.
Is the correct
power supply available?
Electric dryers require 240-volt power supply. Check with a
qualified electrician.
Was a regular fuse used?
Use a time-delay fuse.
Is the dryer door firmly closed?
Was the Start button firmly pressed?
Large loads may require pressing and holding the Start
button for 2-5 seconds.
No heat
Has a household fuse blown, or has a circuit breaker
tripped?
The drum may be turning, but you may not have heat. Electric
dryers use 2 household fuses or breakers. Replace the fuse
or reset the circuit breaker. If the problem continues, call an
electrician.
Unusual
sounds
Has the dryer had a period of non-use?
If the dryer hasn't been used for a while, there may be a
thumping sound during the first few minutes of operation.
Is a coin, button or paper clip caught between the drum
and front or rear of the dryer?
Check the front and rear edges of the drum for small objects.
Clean out pockets before laundering.
Are the four legs installed,
and is the dryer level front to
back and side to side?
The dryer may vibrate if not properly installed. See
"Installation
Instructions."
Is the clothing
knotted
or balled up?
When balled up, the load will bounce, causing the dryer to
vibrate. Separate the load items and restart the dryer.
Are there unusual sounds at any time during a cycle?
You may hear the Dual Action Drying system blower motor
starting, changing speeds, or increasing or decreasing
airflow. These sounds are normal. See "Dual Action Drying
System" in "Dryer Use."
msthe dryer vibrating?
The Dual Action Drying system may be operating the blower
at its maximum speed. This may be required for your
conditions. Verify that your vent meets the requirements listed
in "Installation Instructions."
Dryer displaying
code message
"PF" (power failure), check the following:
Was the drying cycle interrupted
by a power failure?
Press and hold START to restart the dryer.
"AF" (dryer is experiencing
a low airflow condition):
To clear the code, press STOP once and the estimated time
remaining countdown will return to the display. "AF" will
continue to appear with each cycle until the low airflow
condition is resolved.
Try the following:
Clean lint screen.
Check that the vent pipe from the dryer to the wall is clear.
Check at the outside of the home that the vent exhaust hood
is not blocked.
Have your home venting run cleaned professionally.
If the problem continues, call for service. To contact Sears
Service, call 1-800-4-MY-HOM_
(1-800-469-4663)
or see
the back page of this manual.
"F" Variable (F1, F2, F20, etc.) service codes:
Call for service. To contact Sears Service, call
1-800-4-MY-HOME
®(1-800-469-4663}
or see the back page
of this manual.