may vary.
About the controls on the portable room heater,
ge.com
HI
LO
Fan
Tirner
heat
on heat on
only on
on
is displaged
in degrees
Fahrenheit.
00-
+C_7
-0
-@
-@
Portable Heater Control
Controls
Remote Control
[on some models)
Timer Pad (onsome models)
When the heater is on, it can be set to
automaticallg
turn off in 1/2 (0.5) to 9 1/2 (9,5)
hours.
1. Press the Timerpad. The displag will blink.
2. Press the + or - pad to set the desired time
for the unit to stop. (Each time gou touch
the + or- pad, the set time will advance
bg 1/2 hour between 0 and 9_2 hours.)
After settings have been made, the displag
will change back to show the room
temperature.
To cancel the timer, press the Timer pad
and press the Decrease pad until 0.0
appears in the displag.
NOTE: If the Timer was set before a power
outage, it will need to be reset after power
is restored.
O
Displag
Shows the room temperature.
Shows the set
temperature
while setting the temperature
in
LO or HI heat modes. Shows whether set in
LO heat, HI heat or fan mode. Shows time
remaining on timer`
NOTE: The display will change to show the
room temperature after settings hove been
made. To recoil the set temperature, press the
Increaseor Decreasepads.
O
Increase (+) Pad
Use to increase the set temperature (when
in the heat mode) orto increase the timer
shut off time.
O
Decrease (-) Pad
Use to decrease the set temperature (when
in the heat mode),to decreasethe timer
shut off time or to cancel (0.0)the timer.
O
Power Pad
Pressto turn the heater on. It will turn on in the
standbg mode. The displag will show the room
temperature.
Pressagain to tum the heater off.
O
Oscillate Pad (onsomemodels)
Turn on to provide continuous side-to-side
air circulation.
For fixed side-to-side air direction, turn on until
the desired air direction is obtained, then turn
it off.
O
Mode Pad
Pressto set to LOheat, HI heat, fan mode or
to return to the standbg mode.
Heat Mode
When in the HI or LO heat mode, use the
Increase/Decrease
pads to set the desired
temperature
between 40°F and 90°F in I°F
increments.
A thermostat is used to maintain the room
temperature. The heater will cgcle on and off to
keep the room at the set level of comfort. Setthe
thermostat at a higher temperature and the indoor
air will become warmer` Setthe thermostat at a
lower temperature and the indoor air will become
less warm.
Fan Mode
Use the fan mode to provide air circulation
without heating.
Sincethe fan setting does not provide heating,
a temperature setting will not be displaged.